Remote Control Operation
SMS-758 Modem Protection Switch
A–6
MN/SMS758 Rev. 3
A.3.3.2 Backup Modem Address
Address “0” may be used to clear the address field of modem “x”.
Command:
<add/ADD_Bx_yyy”cr”
Response:
>add/ADD_Bx_yyy”cr””lf”]
Status Only:
<add/ADD_Bx”cr”
Response:
>add/ADD_Bx_yyy”cr””lf”]
Where:
x = 1 to 8 (backup modem number).
yyy = 1 to 255 (backup modem address).
A.3.3.3 Prime Modem Interface Type
Command:
<add/INT_x_y”cr”
Response:
>add/INT_x_y”cr””lf”]
Status Only:
<add/INT_x”cr”
Response:
>add/INT_x_y”cr””lf”]
Where:
x = 1 to 8 (prime modem number).
y = 1 (for 15 D), 2 (for V.35), 3 (for RS422), 4 (for DCTN), 5 (for IDR), or 6 (for
OTHER).
A.3.3.4 Backup Modem Interface Type
Command:
<add/INT_Bx_y”cr”
Response:
>add/INT_Bx_y”cr””lf”]
Status Only:
<add/INT_Bx”cr”
Response:
>add/INT_Bx_y”cr””lf”]
Where:
x = 1 or 2 (backup modem number).
y = 1 (for DS1), 2 (for V.35), or 3 (for RS-422).