MCDD-100 MetaCarrier Detection Device
Revision 3
Introduction
MN-MCDD100
1–4
control). SNMP may be used for fully automatic control for dynamic searching of the presence of
the MetaCarrier under the detected carriers within a spectrum. The presence of a MetaCarrier
may be obtained as part of a standard operating procedure or during an interference condition.
•
Manually entered using the MCED-100 HTTP Web Server Interface:
o
Telephone Number
o
Custom Message
•
MCED-100 MetaCarrier™ Embedding Device Installation and Operation Manual
(CEFD P/N MN-MCED100)
•
Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT
•
Sect. 6.3 (ETHERNET-BASED REMOTE PRODUCT MANAGEMENT) SNMP (MIB II
and Private MIB)
•
Sect. 6.4 (ETHERNET-BASED REMOTE PRODUCT MANAGEMENT) Web Server
(HTTP) Interface
Field update of the operating system firmware is possible through file upload via the rear panel
RJ-45 ‘ETHERNET MANAGEMENT’ port.
Chapter 4. UPDATING FIRMWARE
1.2.1
About MetaCarrier
The MetaCarrier operates independent of the modulation, forward error rate, symbol rate, etc.
of the transmission carrier. In configurations where the carrier is encrypted or uses
cryptographic technologies, the CID contained in the MetaCarrier is not affected.
Traditionally, identification of an interfering carrier may involve using a geo-location system
that, in turn, uses the phase offset from an adjacent satellite to triangulate the approximate
location on the surface of the earth where the interference is being generated.
While these tools have been proven useful and invaluable to satellite operators and service
providers, the geo-location products’ methods are imprecise; for example, in densely populated
areas, a helicopter with a feed horn and spectrum analyzer must be used to find the exact
location of the transmission source. The time and costs associated with such methods are
significant.
By contrast, Comtech EF Data’s CID products provide the operator with the interference
source’s identification information within minutes. Once the offending carrier is identified,
appropriate action can be taken to shut down or otherwise remove the identified transmission
from service.
The MCED-100 MetaCarrier Embedding Device’s combined carrier (transmission carrier and
embedded MetaCarrier) creates a composite carrier that results in scalable identification system
that requires minimal power (typically less than 0.1 dB) from the transmission carrier.
Summary of Contents for MetaCarrier MCDD-100
Page 8: ...MCDD 100 MetaCarrier Detection Device Revision 3 Table of Contents MN MCDD100 viii BLANK PAGE ...
Page 30: ...MCDD 100 MetaCarrier Detection Device Revision 3 Installation MN MCDD100 2 6 Notes ...
Page 86: ...MCDD 100 MetaCarrier Detection Device Revision 3 Appendix A MN MCDD100 A 8 Notes ...
Page 87: ......
Page 88: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...