6.4.4.4.2
Status | Alarms
Use this page to view cumulative alarms and stored events information.
Figure 6-9. Status | Alarms page
Alarms
Use the associated drop-down menu to define a designated alarm as Alarm, Fault or Masked,
and then click [Change] to initiate. Note the following:
•
Select Alarm so that the condition triggers a ‘yellow’ alarm.
•
Select Fault so that the condition triggers a unit fault indication.
•
Select Masked so that the condition triggers no alarm.
Click [Refresh] to save any changes and to update the reporting status for all info entries in this
section.
Events
Note that in accordance with European convention, the Events Log shows the date
in DAY-MONTH-YEAR format.
When a fault condition occurs, it is date- and time-stamped and entered into the Stored Events
Log. This log can store up to 255 events. The log also records when the fault condition clears.