Digicast Media Router S2 Receiver CMR-5995 (MR-S2-ASI)
Revision 1
Installation & Initial Configuration
MN-CMR5995-IOM
2-2
•
Test
the router for proper operation.
•
Contact
Comtech EF Data Customer Support if the shipment is:
Incomplete
Physically damaged
Inoperable
2.3
Installation
The CMR-5995 is designed for ease of installation and configuration. Once the unit has
been removed from the packing container, please follow these instructions:
Step
Procedure
1
Place the unit on a flat surface with free airflow, where the LEDs can be clearly observed
and with unrestricted access to the rear panel of the unit.
2
Until the unit has been fully configured, the coaxial connection to the Low Noise Block (LNB)
should NOT be connected to the unit . If the unit will not be powering the LNB, it is
recommended that 'Polarity' (on the 'Tuner' configuration page) be set to 'Off'
3
Connect the DC power connection from the SPU30-102 (external power supply) to the
connection labeled PWR on the back of the unit and tighten the restraining nut to ensure
secure operation.
4
Connect an RJ-45 Ethernet cable (patch cord) to the port labeled ETHERNET and to an
Ethernet concentrator (hub) or switch.
5
Connect a terminal cable P/N CA-TERMINAL (supplied) to the port labeled TERM and to a
PC’s serial port (DB-9), to initially configure the CMR-5995.
6
Connect the AC power (via the IEC power cord) between a standard wall outlet and the
power supply. The Blue LED will illuminate.
7
Upon startup, the LEDs on the front panel may illuminate as follows:
Color
Label
Description
Blue
PWR
Illuminates if power is properly applied
Green
RED
Redundancy indicator
Red
ALARM
May illuminate if the unit is not yet configured
Green
LOCK
Illuminates if the tuner is locked
Green
E-SPD
Ethernet speed indicator
Amber
E-COL
Ethernet collision indicator
Green
E-RX
Flashes if there is Ethernet traffic/activity
Green
E-TX
Green
E-LINK
Illuminates if the Ethernet connection to the Hub/Switch is
operational