Serial Interface Operation
Revision 3
CDM-760 Advanced High-Speed Trunking Modem
MN-CDM760
8–30
Parameter Type
Controller-to-Target
Instruction Code and
Qualifier
Arguments for
Command or
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of Arguments)
Command
Query
Response to
Command
Response to
Query
PIIC
Mode Select
ETS=
ETS?s
2 bytes
Command or Query.
Sets or returns the PIIC interface card mode in the form sm, where:
s=Interface Slot, where:
1=Slot 1
2=Slot 2
x=Mode, where:
For G.703 PIIC module:
0=NONE
1=E3
2=T3
3=STS1
NOTE: G703 PIIC settings other than none will also set the selected G.703 data rate. The unit will adjust the symbol
rate based on the modulation type, code rate, framing, and pilots to keep the selected data rate
For OC3 PIIC module:
0=NONE
1=OC3/STM-1
NOTE: OC3 PIIC settings other than NONE will also set the modem data rate to 155.52 Mbps. The unit will adjust the
symbol rate based on the modulation type, code rate, framing, and pilots to keep the selected data rate.
NOTE: Commands are valid only with the appropriate PIIC interface as indicated above. In addition, the following is true
for various cards.
EXAMPLE: <0/ETS=11 (sets G.703 PIIC module in Slot 1 to E3 mode; sets OC3 PIIC module in Slot 1 to OC3/STM-1
mode)
MultiStream and Single Stream Modes:
To enable MultiStream Mode:
1. Disable all PIIC Interfaces.
2. Enable one or more Gigabit Ethernet Interfaces.
3. Set the SR, ModCod, etc. to meet your requirements.
4. Enable PIIC 1 or PIIC 2 or both interfaces.
To enable PIIC1 or PIIC2 in synchronous interface mode:
1. Disable all PIIC Interfaces.
2. Disable all Gigabit Ethernet Interfaces.
3. Enable PIIC1 or PIIC2.
NOTE: GBEI 1, GBEI 2 and Optical Ethernet must all be disabled before a PIIC can operate in a synchronous
mode.
ETS=
ETS?
ETS *
ETS #
ETS=m
PIIC Rx Buffer Size RBS=
RBS?s
6 bytes
Command or Query.
Sets or returns Rx Buffer Size (in ms), in the form sxxx.x where:
s=Interface Slot, where:
1=Slot 1
2=Slot 2
xxx.x=Rx Buffer Size, in 0.5 ms steps, from 2.0 to 75.0 ms
EXAMPLE: <0/RBS=1032.5 (selects 32.5 ms for Slot 1)
RBS=
RBS?
RBS*
RBS#
RBS=xxx.x
Summary of Contents for CDM-760
Page 2: ......
Page 4: ...ER CDM760 EA4 Rev CO C 0036739...
Page 7: ...BLANK PAGE...
Page 309: ...Appendix B Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 B 6 Notes...
Page 325: ...Appendix D Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 D 6 Notes...
Page 337: ...Appendix F Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 F 8 BLANK PAGE...
Page 349: ...Appendix F Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 F 20 Notes...
Page 357: ...Appendix G Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 G 8 BLANK PAGE...
Page 381: ...Appendix G Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 G 32 Notes...
Page 393: ...Appendix H Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 H 12 Notes...
Page 415: ...Appendix J Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 J 22 Notes...
Page 427: ...Appendix K Revision 4 CDM 760 Advanced High Speed Trunking Modem MN CDM760 K 12 Notes...
Page 440: ......
Page 441: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...