CDD-880 Multi Receiver Router
MN-CDD880
Installation
Revision 2
2–2
Once opened, inspect the shipment:
Step
Task
1
Keep all shipping materials.
2
Check the packing list to make sure the shipment is complete.
3
Inspect the equipment for damage. If damage exists, immediately contact the carrier
and Comtech EF Data to submit a damage report.
4
Read the manual.
2.2
Install the Unit Into a Rack Enclosure
Install the CDD-880 in its assigned position in the rack enclosure (
Figure 2-2
). Use, as required:
•
A standard rack-mounted shelf;
•
User-supplied screws to secure the front panel to the rack enclosure threaded front
mounting rails;
•
Comtech EF Data’s optional KT-0000168 (4”) or KT-0000195 (10”) Rear Support Brackets Kit
(
Figure 2-3
).
For information about custom rack enclosures, contact Comtech EF Data Product Support.
CAUTION – CORRECT GROUNDING PROTECTION IS REQUIRED TO PREVENT PERSONAL
INJURY AND EQUIPMENT DAMAGE.
You must make sure the ground stud on the rear panel of the unit is always connected
to the protective earth.
SUFFICIENT AIR VENTILATION IS REQUIRED.
Make sure there is adequate air ventilation clearance inside the enclosure, especially
at the side. In a rack system where there is high heat discharge, provide forced-air
cooling with top- or bottom-mounted fans or blowers.
The CDD-880 CANNOT have rack slides mounted to the sides of the chassis. Cooling
fans and exhaust vents are provided here – air flow must not be impeded. Comtech EF
Data recommends that an alternate method of support is provided within the rack,
such as standard rack shelves or the optional Rear-Mounting Support Brackets Kit. If
there is any doubt, contact Comtech EF Data Customer Support during normal
business hours.
MAXIMUM AIR TEMPERATURE.
Make sure the air temperature inside the enclosure
never
exceeds 50
°
C (122
°
F).
Summary of Contents for CDD-880
Page 2: ...BLANK PAGE...
Page 14: ...CDD 880 Multi Receiver Router MN CDD880 CD CDD880 Table of Contents Revision 2 xiv BLANK PAGE...
Page 22: ...CDD 880 Multi Receiver Router MN CDD880 Preface Revision 2 xxii Notes...
Page 34: ...CDD 880 Multi Receiver Router MN CDD880 Introduction Revision 2 1 12 Notes...
Page 40: ...CDD 880 Multi Receiver Router MN CDD880 Installation Revision 2 2 6 Notes...
Page 56: ...CDD 880 Multi Receiver Router MN CDD880 Rear Panel Connections Revision 2 3 16 Notes...
Page 134: ...CDD 880 Multi Channel Receiver MN CDD880 Appendix A Revision 2 A 8 Notes...
Page 174: ...CDD 880 Multi Receiver Router MN CDD880 Appendix D Revision 2 D 20 Notes...
Page 182: ...CDD 880 Multi Receiver Router MN CDD880 Appendix E Revision 2 E 8 Notes...
Page 194: ...CDD 880 Multi Receiver Router MN CDD880 Appendix F Revision 2 F 12 Notes...
Page 232: ...CDD 880 Multi Receiver Router MN CDD880 Appendix H Revision 2 H 14 Notes...
Page 233: ......
Page 234: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...