background image

2

Compool Cp3400

System Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Operating Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Control Panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Equipment Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Equipment Status Icons  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Equipment Status Lamps  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Heater Protection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Cleaner Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Canceling Heater and Cleaner Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Temperature Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Fahrenheit/Celsius key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Programming  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Programming  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Programming additional Run Times. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Programming a Time-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Programming a Once-only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Canceling Programs  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Setting the Time of Day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Remote Control at Spa key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Calibration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Power Center. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Equipment keys. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3 - Hour Filter Override  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Sensor Status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Spa-side Remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Spa-side Heat Boost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

System Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Telephone Module  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
2-speed Filter Pump Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Spa Waterfall Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Freeze Protection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Winterizing the System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Problem Solving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Summary of Contents for Cp3400

Page 1: ...Compool Cp3400 POOL SPA CONTROL SYSTEM Installation Operating Instructions 04 08 98 941 1098...

Page 2: ......

Page 3: ...Circuit Board 12 Low Voltage Cables 13 Valve Actuators 13 Gas Heater Connections 14 Water Temperature Sensor 14 Freeze Temperature Sensor 15 Control Panel 16 Modular Crimping Tool 17 System Options 1...

Page 4: ...Programming 29 Programming additional Run Times 29 Programming a Time out 29 Programming a Once only 30 Canceling Programs 30 Setting the Time of Day 30 Remote Control at Spa key 30 Calibration 31 Po...

Page 5: ...unless they are closely supervised at all times Water in excess of 100 degrees Fahrenheit may be hazardous to your health A terminal bar marked for equipment ground only is located inside the high vol...

Page 6: ...duction Package Contents The CP3400 T system includes the following components CP 3400 Control Panel w cable 1 qty LX 3400 Power Center 1 qty CVA 24T Valve Actuator 2 qty PTV 2T 3 Port Valve 2 qty SNS...

Page 7: ...l Cp3400 The CP3400 TL system includes the following components CP 3400 Control Panel w cable 1 qty LX 3400L Power Center 1 qty CVA 24T Valve Actuator 2 qty PTV 2T 3 Port Valve 2 qty SNS KIT2 Sensor K...

Page 8: ...eturn to the other port 4 Plumb 3 4 spa makeup line incorporating a 3 4 ball valve and a 3 4 check valve During pool circulation some of the pool water needs to enter the spa to keep it chemically bal...

Page 9: ...ld be used when distance to panels exceeds 200 or panels are elevated higher than 25 11 Glazed solar panels require a drain valve model HW 5B to allow draining of panels This prevents damage from over...

Page 10: ...the equipment Provide power from the Main panel located at the house to Power Center Power Center without built in Sub panel At the equipment pad mount a 100 amp electrical circuit breaker panel Sub p...

Page 11: ...equipment Water Sensor Solar Sensor Sensor Status Auto Auto Service Press Filter key 2 times quickly Filter Pump On Press Filter key 3 times quickly Filter Pump Off To cancel The 3 hour override can b...

Page 12: ...LOAD 2 R6 LINE 1 LINE 2 LOAD 1 LOAD 2 R7 HIGH VOLTAGE RELAYS FULL LOAD 20AMP LOCKED ROTOR 60AMP Lx3400 SUB PANEL Spa Fill Drain Filter Pump Heater 3 2 1 S P Solar Auto Service IMPORTANT Switch back t...

Page 13: ...NE 1 LINE 2 LOAD 1 LOAD 2 R3 LINE 1 LINE 2 LOAD 1 LOAD 2 R4 LINE 1 LINE 2 LOAD 1 LOAD 2 R5 LINE 1 LINE 2 LOAD 1 LOAD 2 R6 LINE 1 LINE 2 LOAD 1 LOAD 2 R7 HIGH VOLTAGE RELAYS FULL LOAD 20AMP LOCKED ROTO...

Page 14: ...NECTIONS 944 1097 GND HLMP HBST SPA FLTR REM1 REM2 REM3 TRANSFORMER CONNECTIONS AUXILIARY VALVE ACTUATORS INTAKE VALVE ACTUATOR ACTUATOR VALVE RETURN AUX VALVE ACTUATOR 18 10 24 PART PC LX3400 COMPOOL...

Page 15: ...ance is not long enough it is possible to splice in additional wire to lengthen cable Use 3 conductor wire model 3COND CVA To install Valve Actuators 1 Remove knob handle and four cover screws from th...

Page 16: ...Center circuit board connect 2 conductor cable to the HTR terminals 4 If heater has electronic ignition provide high voltage power from the Sub panel Water Temperature Sensor The Water Temperature Sen...

Page 17: ...ment pad To wire the Freeze Temperature Sensor 1 Install the sensor next to the Power Center 2 Run a 2 conductor cable from the sensor to the Power Center 3 At the sensor use crimp connectors included...

Page 18: ...nts Insert mounting anchors included into the three holes 4 Pull cable through large hole in backplate use the three 1 25 screws to mount backplate to wall Use crimping tool to connect modular connect...

Page 19: ...ng from an electrical supply store verify it is designed to crimp 6 position connectors To install the modular connectors 1 Use stripper to remove cable jacket 2 Insert modular connector into crimper...

Page 20: ...c pipe with pvc cement so that the red button will be on top 5 At the Power Center connect Spa side Remote wires to appropriate screw terminals located at bottom of the of the circuit board 6 Connect...

Page 21: ...alve Actuators To install Valve Module 1 Attach Valve Module to the top of the Power Center circuit board 2 Run Valve Actuator cable s to the Valve Module 3 Plug each Valve Actuator cable into the 3 p...

Page 22: ...or and glazing 2 Run a 2 conductor cable from the sensor to the Power Center 3 At the sensor use crimp connectors included to provide waterproof connections Before making connections cut off stripped...

Page 23: ...ircuit AUX1 AUX3 and connect RLY LXD control wire into the appropriate relay socket Telephone Module The Telephone Module model MOD TELSPA allows turning the spa on off from a phone If preferred the T...

Page 24: ...rn on SPEC FNCT configuration switch B W located at the bottom of the Power Center circuit board 4 Program the backwash interval and duration times at the Control Panel See Calibration for details Flo...

Page 25: ...System settings are used to configure the following equipment SOLR Activate solar system HTPMP Activate heatpump as secondary heat source MANHT Activate heater when spa is manually turned on WFAL Act...

Page 26: ...er key verify heater fires Filter pump must also be on 5 Press the Solar key verify solar valve if applicable rotates to solar position If it is 180 degrees out of phase flip the toggle switch on the...

Page 27: ...as needed Equipment Keys Equipment keys activate the Spa Pool and up to 6 additional items Each key can be custom labeled for your specific application To turn equipment on or off press the appropria...

Page 28: ...additional 10 minutes to allow the heater to cool down During this cool down cycle and icon on the display will indicate DELAY Some heaters do not require a cool down period so this function may have...

Page 29: ...o heating For added convenience whenever the spa is manually activated from either the Control Panel or the Spa side Remote the Spa Heat Source Lamp will automatically switch to Heater Turning the spa...

Page 30: ...ey Located behind the right door of the Control Panel is the Temp Display key Press this key to select Fahrenheit or Celsius temperature display Programming Behind the right door of the Control Panel...

Page 31: ...y to set the RUN TIME 6 Press the Program key to end Programming additional Run Times It is possible to program up to four separate START TIME and RUN TIME s for each equipment key Follow the previous...

Page 32: ...w of blinking icons located immediately above the eight Equipment keys 2 Press and hold down the Cancel key for 5 seconds After 5 seconds a continuous alarm will sound until you release the Cancel key...

Page 33: ...ess the Spa Heat Source key 3 Enter correct pool temperature and press Spa Heat Source key 4 Enter correct solar temperature and press Spa Heat Source key 5 Enter correct air temperature and press Spa...

Page 34: ...s for calibrating the temperature sensors Water Sensor Let the pool run for 5 minutes to allow water temperature sensor to accurately pickup current pool water temperature Solar Sensor Put a thermomet...

Page 35: ...the following modes Auto Control Panel and Spa side Remote are enabled Power Center keys are disabled Service Power Center keys are enabled Control Panel and Spa side Remote are disabled A blinking A...

Page 36: ...s particularly useful when adding chemicals to the pool Note The Control System must be in Auto mode to enable these feature To turn the filter pump on press the P key Filter Pump 2 times quickly The...

Page 37: ...at Boost feature it is possible to manually activate the heater and boost the spa temperature for a five minute period This feature can only be activated if the Spa side Remote light is not blinking T...

Page 38: ...ds 2 speed Filter Pump Control The 2 speed filter pump can be switched to high speed under the following conditions Cleaner is on Spa is on Heater is on Solar is on Note When the 2 speed filter is tur...

Page 39: ...37 Compool Cp3400 Winterizing the System In areas where freezing temperatures occur for an extended period of time it is required to consult a qualified service company to winterize your pool...

Page 40: ...Sensor model TS 5L Display shows Err 4 If the Control Panel is not able to communicate with the Power Center the display will show Err 4 Check communication cable and connections Use test cable provi...

Page 41: ...anel Check circuit breakers in the Sub panel and Power Center Check communication cable Clock lost time after power failure Replace battery located on Power Center circuit board System not responding...

Page 42: ...California 94043 For questions repairs replacement parts or information on possible Authorized Service Centers within your vicinity call Compool 800 458 2201 or 415 964 2201 Monday Friday 8 00 5 00 P...

Page 43: ...nt Status Lamps 26 Fahrenheit Celsius key 28 Floor Cleaner Valve 22 FREEZE 23 Freeze Protection 36 Freeze Temperature Sensor 15 Gas Heater Connections 14 Heat Pump or Electric Heater 19 Heater Protect...

Page 44: ...ime of Day 30 Solar Booster Pump Control 20 Solar Heating 20 Spa Waterfall Control 36 Spa side Heat Boost 35 Spa side Remote 18 Spa side Remote 35 SPEC FUNCT Special Functions 23 SYST System 23 System...

Reviews: