9
Compool Cp3400
System Power
System Power provides power to the transformer.
•
To wire System Power
1.
At the Sub-panel, install a circuit breaker for System Power. The system draws less than 1
amp. Do not use a GFCI circuit breaker.
2.
Run appropriate wires from the circuit breaker to the System Power terminal block.
3.
For a 115 volt connection, connect to terminals 2 and 3.
4.
For a 230 volt connection, connect to terminals 1 and 3.
Caution Incorrect wiring will cause permanent damage to the transformer.
Lx3400
SUB-PANEL
Spa
Fill
Drain
Filter
Pump
Heater
3
2
1
S
P
Solar
Auto
Service
IMPORTANT: Switch back to
Auto after servicing equipment.
Water Sensor
Solar Sensor
Sensor
Status
Auto
▲
▲
▲
▲
Auto
Service
Press
Filter
key 2 times quickly.
Filter Pump On:
Press
Filter
key 3 times quickly.
Filter Pump Off:
To cancel:
The 3-hour override can be
cancelled by switching to
Service, and then back to Auto.
Make sure the Auto/Service
key is in the Auto position.
Override Verification:
The Auto lamp will blink
during the 3-Hour Override.
Instructions:
When adding chemicals to the pool,
the filter pump can be set to stay on
for 3 hours -or- stay off
for 3 hours.
This overrides the programming of
the Cp3400 indoor controller on a
one-time basis. The same procedure
can be used on the other equipment
keys 1-3.
3
Hour Filter Override
P
P
B
Freeze Sensor
Lamp ON indicates problem with the
sensor or wires leading to sensor.
Check connections and replace sensor
if necessary.
▲
▲
B.wash