24
Compool Cp3400
AUX1
Activate high speed when AUX1 is on.
SOLR
Activate high speed when solar is on.
PHONE CONTROLS
Phone Controls settings are used to configure the following equipment.
POOL HEAT
Activate pool Heat Source key.
SPA
Activate Spa key.
System Start-up
•
To perform initial start-up
1.
At the Power Center, press the Auto/Service key to select Service mode.
2.
Press the S key, verify the Intake and Return valves rotate to spa position. If either valve is
180 degrees out of phase, flip the toggle switch on the rear of Valve Actuator to reverse
phase (ON1/ON2).
3.
Press Equipment keys (Filter, 1, 2, and 3), verify equipment is being activated.
4.
Press the Heater key, verify heater fires (Filter pump must also be on).
5.
Press the Solar key, verify solar valve (if applicable) rotates to solar position. If it is 180
degrees out of phase, flip the toggle switch on the rear of Valve Actuator to reverse phase
(ON1/ON2).
6.
Check Sensor Status lights. If a light is on, check appropriate sensor wiring and
connections.
7.
Press the Auto/Service key to select Auto mode.
8.
At the Spa-side Remote, press the Red, Yellow, Green, and Blue key, verify equipment is
being activated. Verify the light in the middle of the remote turns on.
9.
At the Control Panel, press Equipment keys (Spa, Pool, 1, 2, 3), verify equipment is being
activated.
10. Affix labels provided to identify Equipment keys at the Control Panel, Power Center, and
Spa-side Remote.
11. Calibrate sensors. See Calibration for details.
12. Program equipment as needed. See Programming for details.