19
Compool Cp3400
SPA
Activates Spa mode.
REM1
Activates AUX1 equipment.
REM2
Activates AUX2 equipment.
REM3
Activates AUX3 equipment
9.
Use labels provided to identify each button on the Spa-side Remote.
Note Install a second Spa-side Remote to control additional functions.
Multiple Control Panels
It is possible to add additional Control Panels.
•
To install an additional Control Panel
1.
Mount Control Panel as described earlier.
2.
Run the communication cable between each Control Panel. Two connectors are provided
on the back of each Control Panel to allow “daisy chaining”.
Note If two Control Panels are being wired where each communication cable is run back to the
Power Center, a coupler (model 6COND-DUAL) is required.
Valve Module
The Valve Module (model MOD-VLV3) allows the system to control three additional Valve
Actuators.
•
To install Valve Module
1.
Attach Valve Module to the top of the Power Center circuit board.
2.
Run Valve Actuator cable(s) to the Valve Module.
3. Plug each Valve Actuator cable into the 3-pin sockets (VLV1, VLV2, or VLV3).
4.
Locate the 2-conductor jumper wires included with Valve Module kit. Each individually
controlled Valve Actuator will require a separate jumper wire.
5.
Connect one end of the jumper wire into CONTROL JUMPERS socket on the Valve
Module. Connect the other end of the jumper wire into the Power Center circuit board at
the appropriate relay socket (SPA, FLTR, AUX1, AUX2, AUX3, B/W, EHTR, SOL
PUMP, 2SPD, FLRCL).
6.
The D.I.P. switch, located at the upper left-side of Valve Module, allows combining the
operation of Valve Actuators.
Heat Pump or Electric Heater
These heaters require a relay kit (model RLY-LX) be added. The HTR connection used for gas
heaters cannot used.
VLV2
VLV3
VLV1
COMPOOL 11040A
MOD-VLV3
VLV1
WITH
VLV2
1
2
O
N
AUXILIARY VALVE
ACTUATORS
VLV2
WITH
VLV3
CONTROL JUMPER
SOCKETS