25
Figure 13. Sine Wave Generator option
To operate the Sine Wave Generator option follows the next steps:
1.
Put the S2 switch in the
SINE WAVE
position.
2.
Attach the 10 Hz sine wave BNC output to an oscilloscope with a 1MΩ impedance input.
3.
Adjust the sine wave amplitude using the coarse and fine adjustments.
4.
Put the S2 switch in the
OFF
position.
5.
Charge and Trigger the pulse per the directions in the user manual.
6.
After the pulse, put the S2 switch in the
SINE WAVE
position to apply the sine wave.
Vacuum Trigger Relay
WARNING:
For this option never exceed 20-second duty cycle
This is high voltage filled with gas of sulfur hexafluoride type SF6, because of the way the gas performs during
switching. SF6 is an excellent insulator but once the switch is closed, if the relay bounces the SF6 becomes easily
ionized and carries the arc current, this makes the relay electronically bounce less and dramatically reduces contact
wear.