![Compleo A01AE11001.11 Operating Instructions Manual Download Page 86](http://html1.mh-extra.com/html/compleo/a01ae11001-11/a01ae11001-11_operating-instructions-manual_2647130086.webp)
86
A01Axxxxxx.xx | 04
2022-11
9.1.26
DclnsulationTestFailureOnCharge (3)
Name
DclnsulationTestFailureOnCharge
Area
Connector (DC)
Description
The insulation test during the charging process has found an error.
Reported by:
Connector
Handling
•
The charging process is aborted
•
The error is shown on the display
Indication on display 3
Action
Switch the complete charging system off and on again. Notify customer
service if the error persists.
9.1.27
samTransactionMemoryFull (4)
Name
samTransactionMemoryFull
Area
Connector
Description
The error occurs when the SAM has no more free memory for new charging
processes.
Reported by:
SAMConnector
Handling
•
The charging process is aborted
•
The error is shown on the display
•
No new charging process possible
Indication on display 4
Action
No action possible by operator. Notify customer service.
9.1.28
samEVSEIDMemoryFull (5)
Name
samEVSEIDMemoryFull
Area
Connector
Description
The error occurs when the SAM has no more free memory for new
configuration parameters.
Reported by:
Connector
Handling
•
The charging process is aborted
•
The error is shown on the display
•
No new charging process possible
Indication on display 5
Action
No action possible by operator. Notify customer service.
Summary of Contents for A01AE11001.11
Page 100: ...Annexes 100 A01Axxxxxx xx 04 2022 11 13 Annexes 13 1 Housing dimensions...
Page 105: ...Annexes 2022 11 A01Axxxxxx xx 04 105 13 3 EU Declaration of Conformity...
Page 106: ...Annexes 106 A01Axxxxxx xx 04 2022 11...
Page 107: ...Annexes 2022 11 A01Axxxxxx xx 04 107...
Page 108: ...Annexes 108 A01Axxxxxx xx 04 2022 11...
Page 109: ...Annexes 2022 11 A01Axxxxxx xx 04 109...
Page 110: ...Annexes 110 A01Axxxxxx xx 04 2022 11...
Page 111: ...Annexes 2022 11 A01Axxxxxx xx 04 111 Notes...