![Compleo A01AE11001.11 Operating Instructions Manual Download Page 76](http://html1.mh-extra.com/html/compleo/a01ae11001-11/a01ae11001-11_operating-instructions-manual_2647130076.webp)
76
A01Axxxxxx.xx | 04
2022-11
8
Malfunctions
8.1
Internal errors
•
If the display shows "Internal error", the charging station must be disconnected from the mains.
NOTE
For charging systems that are not equipped with a display, the start page of the "DUCTO"
configuration software must be called up for error detection (see chapter 6.3 Configuration of the
charging system with Compleo DUCTO, page 52).
The DUCTO start page displays the status of the charging system and possible error codes in the
event of a fault.
8.2
Residual current circuit breaker (RCCB)
In the event of a residual current, the residual current circuit breaker trips and the charging system is
switched off.
To switch on again, proceed as follows:
1.
Eliminate the cause of the error.
2.
Activate the residual current circuit breaker by pushing up the locking slide on the front of the
housing.
The system starts up.
8.3
Circuit breaker (MCB)
In the event of an overcurrent, the affected circuit breaker trips and the charging system is switched
off.
To switch on again, proceed as follows:
1.
Eliminate the cause of the error.
2.
Reactivate the circuit breaker at the sub-distribution.
The system starts up.
Summary of Contents for A01AE11001.11
Page 100: ...Annexes 100 A01Axxxxxx xx 04 2022 11 13 Annexes 13 1 Housing dimensions...
Page 105: ...Annexes 2022 11 A01Axxxxxx xx 04 105 13 3 EU Declaration of Conformity...
Page 106: ...Annexes 106 A01Axxxxxx xx 04 2022 11...
Page 107: ...Annexes 2022 11 A01Axxxxxx xx 04 107...
Page 108: ...Annexes 108 A01Axxxxxx xx 04 2022 11...
Page 109: ...Annexes 2022 11 A01Axxxxxx xx 04 109...
Page 110: ...Annexes 110 A01Axxxxxx xx 04 2022 11...
Page 111: ...Annexes 2022 11 A01Axxxxxx xx 04 111 Notes...