78
A01Axxxxxx.xx | 04
2022-11
9.1.2
GroundFailure (B)
Name
GroundFailure
Area
Connector (AC/ DC)
Description
OCPP1.6: Ground fault circuit interrupter has been activated. The RCD switch,
the circuit breaker or the 6mA sensor of the connector has tripped,
protective function.
Reported by:
Station
Handling
•
The error is shown on the display
Indication on display B
Action
Have a qualified electrician check the RCD switch on site. Switch the FI switch
on again. Notify customer service if the error persists.
9.1.3
HighTemperature (C)
Name
HighTemperature
Area
Station
Description
OCPP1.6: Temperature inside Charge Point is too high. Temperature inside
Charge Point is too high.
Reported by:
Station
Handling
•
The error is shown on the display
Indication on display C
Action
No action possible by operator. Notify customer service.
9.1.4
InternalError (D)
Name
InternalError
Area
Station
Description
OCPP1.6: Error in internal hardware or software component. For example,
errors during initialisation of the socket module.
Reported by:
Connector
Handling
•
The connector terminates the charging process
•
The error is shown on the display
Indication on display D
Action
No action possible by operator. Notify customer service.
Summary of Contents for A01AE11001.11
Page 100: ...Annexes 100 A01Axxxxxx xx 04 2022 11 13 Annexes 13 1 Housing dimensions...
Page 105: ...Annexes 2022 11 A01Axxxxxx xx 04 105 13 3 EU Declaration of Conformity...
Page 106: ...Annexes 106 A01Axxxxxx xx 04 2022 11...
Page 107: ...Annexes 2022 11 A01Axxxxxx xx 04 107...
Page 108: ...Annexes 108 A01Axxxxxx xx 04 2022 11...
Page 109: ...Annexes 2022 11 A01Axxxxxx xx 04 109...
Page 110: ...Annexes 110 A01Axxxxxx xx 04 2022 11...
Page 111: ...Annexes 2022 11 A01Axxxxxx xx 04 111 Notes...