background image

10

11

1

1x set of lead wire 

(blue/ red/ yellow/ green)

2

1x USB charging cable

3

1x snap electrode package 

(4pcs of small electrode, 2pcs of large electrode)

4

1x quick start guide

5

1x warranty card

6

1x carrying case

7

1x Compex® Wired 3.0 stimulator

2

6

7

3

5

4

1

ACCESSORIES & PRODUCTS

INTRODUCTION

HOW DOES ELECTROMUSCULAR STIMULATION (EMS) WORK?

The principle of electrostimulation is to stimulate nerve fibers by means of electrical impulses 

transmitted by electrodes. The electrical pulses generated by Compex® Wired 3.0 stimulator are 

high quality pulses - offering safety, comfort and efficiency.
The motor nerves, to stimulate a muscular response. The quantity and the benefits obtained 

depend on the stimulation parameters and this is known as electro- muscular stimulation (EMS).

Electromuscular Stimulation (EMS)

In voluntary activity, the order for muscular work comes from the brain, which sends a command 

to the nerve fibers in the form of an electrical signal. This signal is then transmitted to the 

muscular fibers, which contract. The principle of electrostimulation accurately reproduces the 

process observed during a voluntary contraction. The stimulator sends an electrical current 

impulse to the nerve fibers, exciting them. This excitation is then transmitted to the muscular 

fibers causing a basic mechanical response (= muscular twitch). The latter constitutes the 

basic requirement for muscular contraction. This muscular response is completely identical to 

muscular work controlled by the brain. In other words, the muscle cannot distinguish whether 

the command comes from the brain or from the stimulator. The parameters of the Compex® 

Wired 3.0 programs (number of impulses per second, contraction time, rest time, total program 

time) subject the muscles to different types of work, according to muscular fibers. In fact, 

different types of muscular fibers may be distinguished according to their respective contraction 

speed: slow, intermediate and fast fibers.
Fast fibers will obviously predominate in a sprinter, while a marathon runner will have more slow 

fibers. With a good knowledge of human physiology and a perfect mastery of the stimulation 

parameters of the various programs, muscular work can be directed very precisely towards the 

desired goal (muscular reinforcement, increased blood flow, firming up, etc.).

Summary of Contents for WIRED 3.0

Page 1: ...WIRED 3 0 Muscle Stimulators Edge 3 0 Performance 3 0 Sport Elite 3 0 READ THE MANUAL BEFORE OPERATING THIS PRODUCT...

Page 2: ...ody parts required for normal function Critical ischemia of lower limb Seriously compromised oxygen carrying blood flow to the legs feet and toes lower limb that may result in loss of the limb if left...

Page 3: ...contraindication indicates a condition or situation in which a device should not be used NOTE DANGEROUS VOLTAGE Text with a Dangerous Voltage indicator serves to inform the user of possible hazards re...

Page 4: ...lation session on a person who is standing The first five minutes of stimulation must always be performed on a person who is sitting or lying down In rare instances people of a nervous disposition may...

Page 5: ...ive medium or alternate electrode placement If you have suspected or diagnosed heart disease you should follow precautions recommended by your physician If you have suspected or diagnosed epilepsy you...

Page 6: ...imulation accurately reproduces the process observed during a voluntary contraction The stimulator sends an electrical current impulse to the nerve fibers exciting them This excitation is then transmi...

Page 7: ...referred to as gates These gates determine which impulses are allowed to continue to the brain The gates prevent the brain from receiving too much information too quickly Since the same nerve cannot...

Page 8: ...cm 12 9mA in Always turn off the stimulator before moving or removing any electrodes during a session Do not place the electrodes in water Do not apply solvents of any kind to the electrodes For best...

Page 9: ...ecome directly accessible after turning on the device NOTE Programs vary depending on device The programs done will automatically be placed in the favorites menu The favorites menu can contain up to 1...

Page 10: ...r selection A Select the desired level B Confirm your selection C Return to the previous step Note if the level option in setting is turned off this step would be canceled D HOW TO ACCESS SETTINGS The...

Page 11: ...eans the corresponding channel is selected After user choose the desired channel press the central confirmation button to confirm your selections then follow the tips on screen press up to start to pr...

Page 12: ...phase relaxation cycle These are warm up recovery or even pain type program During this type of program frequency variations can occur A Warm up phase B Work phase C Relaxation phase D Recovery phase...

Page 13: ...y is completely discharged It is no longer possible to use the device Recharge it immediately The charge state of the battery is indicated by a small battery icon on the top right screen A BATTERY LEV...

Page 14: ...pe of effort are for example the 400 and 800 meters one kilometer cycle races and 100 meters swimming It is appropriate for many other sports based on duration such as cycling which makes repeated dem...

Page 15: ...by placing the electrode connected to the positive pole red connection strategically When working with a muscle stimulation program involving muscle contractions it is important to place the positive...

Page 16: ...th others When removing your pads from your skin peel from the side of the pad Do not pull the pad off by the wire When you store your electrode pads after your session make sure to stick them on the...

Page 17: ...ls REACH Caution This is an indication for protection against ingress of water and particulate matter The mark IP22 on your unit means your unit is protected against solid foreign objects of 12 5mm di...

Page 18: ...11 RF Emissions Group 1 The Compex Wired 3 0 uses RF energy only for its internal operation Consequently its RF emissions are very low and are unlikely to interfere with any adjacent electrical device...

Page 19: ...ngth in the location in which the Compex Wired 3 0 are used exceeds the applicable RF compliance level above the Compex Wired 3 0 should be observed to verify normal operation If abnormal performance...

Page 20: ...ilure in the Product caused by product misuse including but not limited to the failure to provide reasonable and required maintenance or any use that is inconsistent with the Product User Manual COMPA...

Page 21: ...40 41 CONTACTINFORMATION Distributed By DJO LLC 1430 Decision Street Vista CA 92081 1 877 266 7398 877 COMPEX8 JKH Health Co LTD Shajing Baoan District Shenzhen China Made in China...

Page 22: ...t 2020 by DJO LLC Individual results may vary Neither DJO LLC nor any of its subsidiaries dispense medical advice The contents of this document do not constitute medical advice Rather please consult y...

Reviews: