A: EMS TRAINING PROGRAMS

Note: 

For the 4 basic workout programs: Endurance, Resistance, Strength, Explosive Strength, 

we advise you to consult the training planner on our website compex.com. An interactive 

question and answer system takes you to a personalized training plan.The Compex® Wired 3.0 

provides four muscle stimulation training programs. They correspond to the type of muscle 

performance the athlete wishes to improve or maintain. These training programs are:
The Compex® Wired 3.0 provides four muscle stimulation training programs. They correspond 

to the type of muscle performance the athlete wishes to improve or maintain. These training 

programs are:

Endurance  |  Strength  |  Resistance  |  Explosive Strength

Each of these four training programs offers five different working levels that enable the amount 

of work to be gradually increased.

STRENGTH: 

The Compex Strength program imposes a high and instantaneous power working 

level on muscle fibers during tetanic contractions. These contractions are separated by long 

periods of rest. The result is an average medium power working level. This program is intended 

to increase the maximum strength of muscle contraction, which is carried out isometrically or 

dynamically. It is specifically designed for sports characterized by a need for maximum but 

very brief strength contractions. Weight lifting is a typical sport of this kind. This program is 

also appropriate for any type of sports requiring a gain in strength on a specific muscle (cycling,  

short distance running, soccer, etc.).

ENDURANCE: 

The Compex Endurance program imposes an average medium working level on 

muscle fibers. This working level is maintained over a long period (40 minutes per session). 

The Endurance program particularly activates the aerobic metabolism of the fibers during the 

stimulation session. The purpose is to increase the time the muscle is able to maintain a medium 

level of working power or the average power level the muscle is able to maintain for extended 

periods of time. The program may be used in most physical preparations to establish or improve 

basic muscle endurance. It is designed to increase the average intensity of muscle effort that 

must be maintained over a long period. It is most appropriate for athletes engaged in endurance 

sports such as marathon, triathlon, cycling, etc.

RESISTANCE: 

The Compex® Resistance program imposes an average high power working 

level on muscle fibers. This working level is maintained over a short period (12 minutes per 

session). The Resistance program activates the anaerobic metabolism of muscle fibers during 

the stimulation session and induces the production of lactic acid. It is intended to increase the 

time the muscle is able to maintain a high power working level (close to its maximum) or the 

average power working level the muscle is able to maintain for a short duration. It is designed 

for sporting activities, which are characterized by a need for intense (close to the maximum) 

efforts to be maintained or repeated to approach the limit of muscle exhaustion. Sports requiring 

this type of effort are, for example, the 400 and 800 meters, one-kilometer cycle races and 100 

meters swimming. It is appropriate for many other sports based on duration, such as cycling, 

which makes repeated demands on muscle resistance.

EXPLOSIVE STRENGTH: 

The purpose of the Compex Explosive Strength program is to increase 

the speed with which maximum muscle strength can be supplied. It is designed to improve 

performance in sporting activities of very brief duration such as jumps, sprints and throwing. 

To ensure a progressive approach in the muscle stimulation training, you are strongly advised 

not to use this program without having previously worked through a cycle of sessions using the 

Strength program. 

MUSCLE RELAXATION: 

The Compex Muscle Relaxation program produces gentle muscle 

twitches, like a massage, to facilitate recovery from muscle fatigue and to help recover muscle 

strength after training sessions and competitions. 

POTENTIATION: 

The Compex Potentiation program produces the physiological muscular 

phenomenon known as “Twitch potentiation”. A specific system of stimulation increases the 

amplitude and the speed of the elementary muscle twitch response of muscle fibers, more 

particularly of fast fibers. A potentiated muscle gains in velocity and reaches its maximum 

strength more easily and rapidly. This program is recommended before performing a sprint,         

a jump or a throw. Applied briefly just before the beginning of a competition, it offers immediate, 

well potentiated muscle fibers and an optimal level of performance to basketball, soccer or 

volleyball players.

B: SPECIALIZED EMS TRAINING PROGRAMS

The Compex® Wired 3.0 also offers six special muscle training programs. Their objective is to 

prepare muscles for explosive motions or to facilitate recovery after active muscle training 

and competition:

•  Muscle relaxation
•  Potentiation
•  Training Recovery
•  Competition Recovery
•  Pre-warm up
•  Pain Relief TENS

C: TENS PROGRAMS

TRAINING RECOVERY: 

The Compex Training Recovery cool-down program produces muscle 

twitches at a very low frequency. Those twitches act like a massage and induce an increase in 

blood flow. They are responsible for a faster reduction of the lactic acid blood level (much better 

than mere rest) and accelerate the exchanges between muscle fibers and blood. Consequently, 

the stimulated muscles recuperate better from fatigue and the athlete has a feeling of relaxation 

and muscle lightness. This type of cool- down program is recommended after hard training 

sessions and competitions. It is particularly useful after sports requiring long duration efforts, 

combining endurance and resistance (cycling, marathon, triathlon, mountain-bike, etc.). The same 

is applicable to sports that require shorter efforts (basketball, soccer, football).

PAIN RELIEF TENS: 

The Pain Relief TENS program is used to alleviate localized pain

COMPETITION RECOVERY: 

The Compex Competition Recovery   program is a sub-set of the 

Training Recovery program that produces a very low constant frequency to induce a gentle 

muscle contraction and vibration to increase in blood flow. This program should be used after 

training sessions and competitions.

PRE-WARMUP: 

The Compex Pre-Warmup program helps muscles to get ready and should be 

used before training sessions and before competitions. 

Summary of Contents for WIRED 3.0

Page 1: ...WIRED 3 0 Muscle Stimulators Edge 3 0 Performance 3 0 Sport Elite 3 0 READ THE MANUAL BEFORE OPERATING THIS PRODUCT...

Page 2: ...ody parts required for normal function Critical ischemia of lower limb Seriously compromised oxygen carrying blood flow to the legs feet and toes lower limb that may result in loss of the limb if left...

Page 3: ...contraindication indicates a condition or situation in which a device should not be used NOTE DANGEROUS VOLTAGE Text with a Dangerous Voltage indicator serves to inform the user of possible hazards re...

Page 4: ...lation session on a person who is standing The first five minutes of stimulation must always be performed on a person who is sitting or lying down In rare instances people of a nervous disposition may...

Page 5: ...ive medium or alternate electrode placement If you have suspected or diagnosed heart disease you should follow precautions recommended by your physician If you have suspected or diagnosed epilepsy you...

Page 6: ...imulation accurately reproduces the process observed during a voluntary contraction The stimulator sends an electrical current impulse to the nerve fibers exciting them This excitation is then transmi...

Page 7: ...referred to as gates These gates determine which impulses are allowed to continue to the brain The gates prevent the brain from receiving too much information too quickly Since the same nerve cannot...

Page 8: ...cm 12 9mA in Always turn off the stimulator before moving or removing any electrodes during a session Do not place the electrodes in water Do not apply solvents of any kind to the electrodes For best...

Page 9: ...ecome directly accessible after turning on the device NOTE Programs vary depending on device The programs done will automatically be placed in the favorites menu The favorites menu can contain up to 1...

Page 10: ...r selection A Select the desired level B Confirm your selection C Return to the previous step Note if the level option in setting is turned off this step would be canceled D HOW TO ACCESS SETTINGS The...

Page 11: ...eans the corresponding channel is selected After user choose the desired channel press the central confirmation button to confirm your selections then follow the tips on screen press up to start to pr...

Page 12: ...phase relaxation cycle These are warm up recovery or even pain type program During this type of program frequency variations can occur A Warm up phase B Work phase C Relaxation phase D Recovery phase...

Page 13: ...y is completely discharged It is no longer possible to use the device Recharge it immediately The charge state of the battery is indicated by a small battery icon on the top right screen A BATTERY LEV...

Page 14: ...pe of effort are for example the 400 and 800 meters one kilometer cycle races and 100 meters swimming It is appropriate for many other sports based on duration such as cycling which makes repeated dem...

Page 15: ...by placing the electrode connected to the positive pole red connection strategically When working with a muscle stimulation program involving muscle contractions it is important to place the positive...

Page 16: ...th others When removing your pads from your skin peel from the side of the pad Do not pull the pad off by the wire When you store your electrode pads after your session make sure to stick them on the...

Page 17: ...ls REACH Caution This is an indication for protection against ingress of water and particulate matter The mark IP22 on your unit means your unit is protected against solid foreign objects of 12 5mm di...

Page 18: ...11 RF Emissions Group 1 The Compex Wired 3 0 uses RF energy only for its internal operation Consequently its RF emissions are very low and are unlikely to interfere with any adjacent electrical device...

Page 19: ...ngth in the location in which the Compex Wired 3 0 are used exceeds the applicable RF compliance level above the Compex Wired 3 0 should be observed to verify normal operation If abnormal performance...

Page 20: ...ilure in the Product caused by product misuse including but not limited to the failure to provide reasonable and required maintenance or any use that is inconsistent with the Product User Manual COMPA...

Page 21: ...40 41 CONTACTINFORMATION Distributed By DJO LLC 1430 Decision Street Vista CA 92081 1 877 266 7398 877 COMPEX8 JKH Health Co LTD Shajing Baoan District Shenzhen China Made in China...

Page 22: ...t 2020 by DJO LLC Individual results may vary Neither DJO LLC nor any of its subsidiaries dispense medical advice The contents of this document do not constitute medical advice Rather please consult y...

Reviews: