background image

8

9

ADVERSE REACTIONS

1.  You may experience skin irritation and burns beneath the stimulation electrodes applied to 

your skin.

2. You may experience headache and other painful sensations during or following the 

application of electrical stimulation near your eyes and to your head and face.

3. You should stop using the device and should consult with your physician if you experience 

adverse reactions from the device.

A

 

Silicone sleeve

B

 

LCD display

C

 

Channel LED indicators

D

 

Channel buttons

E

 

Key Up

F

 

Key Left

G

 

USB charging socket 

(Push aside the rubber cover  
then directly plug in the USB  
charging cable)

H

 

Four electrode sockets

I

 

Four electrode cables

J

 

On/Off switch

K

 

Key Right

L

 

Confirmation button

M

 

Key Down

A

J

K

L

M

B

E
F
G

C

H

D

Sport Elite 3.0 pictured

PRODUCT OVERVIEW

NOTE:

 You are strongly advised to carefully read the safety precautions and contraindications 

described at the start of this manual prior to using your stimulator.

•  TENS is a symptomatic treatment and, as such, suppresses the sensation of pain that would 

otherwise serve as a protective mechanism.

•  Effectiveness is highly dependent upon patient selection by a practitioner qualified in the 

management of pain patients.

•  The safety of electrical stimulation during pregnancy has not been established.
•  You may experience skin irritation or hypersensitivity due to the electrical stimulation 

or electrical conductive medium (gel). The irritation can usually be reduced by using an 

alternate conductive medium, or alternate electrode placement.

•  If you have suspected or diagnosed heart disease, you should follow precautions 

recommended by your physician.

•  If you have suspected or diagnosed epilepsy, you should follow precautions recommended 

by your physician.

•  Use caution if you have a tendency to bleed internally, such as following an injury or fracture.
•  Consult with your physician prior to using the device after a recent surgical procedure, 

because stimulation may disrupt the healing process.

•  Use caution if stimulation is applied over the menstruating or pregnant uterus.
•  Use caution if stimulation is applied over areas of skin that lack normal sensation.
•  Keep this device out of the reach of children.
•  Use this device only with the leads, electrodes, and accessories recommended by the manufacturer.
•   Do not allow any foreign bodies (soil, water, metal, etc.) to penetrate the device. Do not 

puncture the enclosure of stimulator.

•  This unit should be operated in temperatures between 32 °F and 113°F (0°C and 45°C), atmospheric 

pressures between 700 and 1060 hPa and Relative Humidity ranging from 30%-75%.

•   Sudden temperature changes can cause condensation to build up inside the stimulator.      

To prevent this, allow it to reach ambient temperature before use.

•  Electrodes should not be shared with other persons. Each person should have their own  

set of electrodes; otherwise, undesirable skin reactions may occur.

•  Self-adhesive electrodes should be replaced if they no longer stick firmly to the skin.
•  Never store the system in a car under the sun or in any other place in direct line with sunbeam.
•  Do not use in the presence of flammable anesthetics
•  Do not use in an oxygen rich environment

Summary of Contents for WIRED 3.0

Page 1: ...WIRED 3 0 Muscle Stimulators Edge 3 0 Performance 3 0 Sport Elite 3 0 READ THE MANUAL BEFORE OPERATING THIS PRODUCT...

Page 2: ...ody parts required for normal function Critical ischemia of lower limb Seriously compromised oxygen carrying blood flow to the legs feet and toes lower limb that may result in loss of the limb if left...

Page 3: ...contraindication indicates a condition or situation in which a device should not be used NOTE DANGEROUS VOLTAGE Text with a Dangerous Voltage indicator serves to inform the user of possible hazards re...

Page 4: ...lation session on a person who is standing The first five minutes of stimulation must always be performed on a person who is sitting or lying down In rare instances people of a nervous disposition may...

Page 5: ...ive medium or alternate electrode placement If you have suspected or diagnosed heart disease you should follow precautions recommended by your physician If you have suspected or diagnosed epilepsy you...

Page 6: ...imulation accurately reproduces the process observed during a voluntary contraction The stimulator sends an electrical current impulse to the nerve fibers exciting them This excitation is then transmi...

Page 7: ...referred to as gates These gates determine which impulses are allowed to continue to the brain The gates prevent the brain from receiving too much information too quickly Since the same nerve cannot...

Page 8: ...cm 12 9mA in Always turn off the stimulator before moving or removing any electrodes during a session Do not place the electrodes in water Do not apply solvents of any kind to the electrodes For best...

Page 9: ...ecome directly accessible after turning on the device NOTE Programs vary depending on device The programs done will automatically be placed in the favorites menu The favorites menu can contain up to 1...

Page 10: ...r selection A Select the desired level B Confirm your selection C Return to the previous step Note if the level option in setting is turned off this step would be canceled D HOW TO ACCESS SETTINGS The...

Page 11: ...eans the corresponding channel is selected After user choose the desired channel press the central confirmation button to confirm your selections then follow the tips on screen press up to start to pr...

Page 12: ...phase relaxation cycle These are warm up recovery or even pain type program During this type of program frequency variations can occur A Warm up phase B Work phase C Relaxation phase D Recovery phase...

Page 13: ...y is completely discharged It is no longer possible to use the device Recharge it immediately The charge state of the battery is indicated by a small battery icon on the top right screen A BATTERY LEV...

Page 14: ...pe of effort are for example the 400 and 800 meters one kilometer cycle races and 100 meters swimming It is appropriate for many other sports based on duration such as cycling which makes repeated dem...

Page 15: ...by placing the electrode connected to the positive pole red connection strategically When working with a muscle stimulation program involving muscle contractions it is important to place the positive...

Page 16: ...th others When removing your pads from your skin peel from the side of the pad Do not pull the pad off by the wire When you store your electrode pads after your session make sure to stick them on the...

Page 17: ...ls REACH Caution This is an indication for protection against ingress of water and particulate matter The mark IP22 on your unit means your unit is protected against solid foreign objects of 12 5mm di...

Page 18: ...11 RF Emissions Group 1 The Compex Wired 3 0 uses RF energy only for its internal operation Consequently its RF emissions are very low and are unlikely to interfere with any adjacent electrical device...

Page 19: ...ngth in the location in which the Compex Wired 3 0 are used exceeds the applicable RF compliance level above the Compex Wired 3 0 should be observed to verify normal operation If abnormal performance...

Page 20: ...ilure in the Product caused by product misuse including but not limited to the failure to provide reasonable and required maintenance or any use that is inconsistent with the Product User Manual COMPA...

Page 21: ...40 41 CONTACTINFORMATION Distributed By DJO LLC 1430 Decision Street Vista CA 92081 1 877 266 7398 877 COMPEX8 JKH Health Co LTD Shajing Baoan District Shenzhen China Made in China...

Page 22: ...t 2020 by DJO LLC Individual results may vary Neither DJO LLC nor any of its subsidiaries dispense medical advice The contents of this document do not constitute medical advice Rather please consult y...

Reviews: