PM1326
1
1
2
3
4
5
6
6
4-3. CONNECTING WELDING GUN, VOLTAGE CLAMP AND WELD CABLE
1.- REMOTE 14 CABLE
2.- SHIELDING GAS VALVE INLET
3.- FUSE F1
4.- SWITCH S1
5.- WIRE FEED INLET
6.- CABLE TO WELDING
POWER SOURCE
4-4. CONNECTING 14-PIN PLUG
3
OUTPUT
(CONTACTOR)
INFORMATION
Socket
REMOTE-14
A
B
I
J
G
K
C
E
D
F
H
24 V a.c. Protected by CB2 (10 Amperes).
Contact closure to "A" completes 24 V a.c. contactor control circuit.
120 V a.c. Protected by CB1(10 Amperes).
Contact closure to "I" completes 120 V a.c. contactor control circuit.
Circuit common for 24 and 120 V a.c. circuits.
Chassis common.
Command reference 10 V d.c.
0 to +10 V d.c. input command signal from remote control.
Remote control circuit common.
Current feedback 0-10 V d.c. 1 Volt per100 weld output Amperes.
Voltage feedback 0-10 V d.c. 1 Volt per 10 weld output Volts
NOTE: Remaining sockets are not used
G N D
REMOTE OUTPUT
CONTROL
A / V