______________________
Note
_______________________
Host port SCSI ID assignments are not linked to the physical port
when fair arbitration is disabled.
The DS-DWZZH-05 reserves SCSI ID 7 regardless of whether fair
arbitration is enabled or not.
3.6.1.2.3 DS-DWZZH-05 Address Configurations
The DS-DWZZH-05 has two addressing modes: wide addressing mode and
narrow addressing mode. With either addressing mode, if fair arbitration is
enabled, each hub port is assigned a specific SCSI ID. This allows the fair
arbitration logic in the hub to identify the SCSI ID of the device participating
in the arbitration phase of the fair arbitration cycle.
_____________________
Caution
_____________________
If fair arbitration is enabled, The SCSI ID of the host adapter
must match the SCSI ID assigned to the hub port. Mismatching
or duplicating SCSI IDs will cause the hub to hang.
SCSI ID 7 is reserved for the DS-DWZZH-05 whether fair
arbitration is enabled or not.
Jumper W1, accessible from the rear of the DS-DWZZH-05 (See Figure 3–3),
determines which addressing mode is used. The jumper is installed to select
narrow addressing mode. If fair arbitration is enabled, the SCSI IDs for the
host adapters are 0, 1, 2, and 3 (See the port numbers not in parentheses
in Figure 3–4). The controller ports are assigned SCSI IDs 4 through 6,
and the hub uses SCSI ID 7.
If jumper W1 is removed, the host adapter ports assume SCSI IDs 12,
13, 14, and 15. The controllers are assigned SCSI IDs 0 through 6. The
DS-DWZZH-05 retains the SCSI ID of 7.
Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware 3–13
Summary of Contents for TruCluster Server AA-RHGWB-TE
Page 16: ......
Page 22: ...cluster Bold text indicates a term that is defined in the glossary xxii About This Manual...
Page 52: ......
Page 78: ......
Page 110: ......
Page 174: ......
Page 250: ......
Page 282: ......
Page 302: ......
Page 304: ......
Page 315: ...Y Y cables connecting devices with 9 6 supported 2 10 Index 11...
Page 316: ......
Page 318: ......