2.10 SCSI Terminators and Trilink Connectors
Table 2–4 describes the supported trilink connectors and SCSI terminators
and the context in which you would use them.
Table 2–4: Supported SCSI Terminators and Trilink Connectors
Trilink
Connector or
Terminator
Den-
sity
Pins
Configuration Use
H885-AA
Three
68-pin
Trilink connector that attaches to high-density,
68-pin cables or devices, such as a KZPSA-BB,
KZPBA-CB, HSZ40, HSZ50, or the differential
side of a SCSI signal converter. Can be
terminated with an H879-AA terminator to
provide external termination.
H8574-A or
H8860-AA
Low
50-pin
Terminates a TZ885 or TZ887 tape drive.
341102-001
High
50-pin
Terminates a Compaq 20/40 GB DLT Tape Drive
H879-AA
High
68-pin
Terminates an H885-AA trilink connector
or BN21W-0B Y cable.
H8861-AA
VHDCI 68-pin
VHDCI trilink connector that attaches to VHDCI
68-pin cables, UltraSCSI BA356 JA1, and HSZ70
or HSZ80 RAID controllers. Can be terminated
with an H8863-AA terminator if necessary.
H8863-AA
VHDCI 68-pin
Terminate a VHDCI trilink connector.
The requirements for trilink connectors are as follows:
•
If you connect a SCSI cable to a trilink connector, do not block access to
the screws that mount the trilink, or you will be unable to disconnect the
trilink from the device without disconnecting the cable.
•
Do not install an H885-AA trilink if installing it will block an adjacent
peripheral component interconnect (PCI) port. Use a BN21W-0B Y cable
instead.
Hardware Requirements and Restrictions 2–11
Summary of Contents for TruCluster Server AA-RHGWB-TE
Page 16: ......
Page 22: ...cluster Bold text indicates a term that is defined in the glossary xxii About This Manual...
Page 52: ......
Page 78: ......
Page 110: ......
Page 174: ......
Page 250: ......
Page 282: ......
Page 302: ......
Page 304: ......
Page 315: ...Y Y cables connecting devices with 9 6 supported 2 10 Index 11...
Page 316: ......
Page 318: ......