3-36
Compaq ProLiant ML350 Generation 2 Server Setup and Installation Guide
Compaq Confidential – Need to Know Required
Writer: Jennifer Hayward Project: Compaq ProLiant ML350 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 236843-002 File Name: d-ch3 Hardware Options Installation.doc Last Saved On: 9/5/01 12:33 PM
Removing a Processor Power Module
1. Open the latches of the PPM slot .
2. Remove the PPM from the slot .
2
1
1
Figure 3-35. Removing a Processor Power Module (PPM)
Replacing Batteries
WARNING:
The system board contains a lithium battery. There is a risk of fire
and chemical burn if the battery is improperly handled. Do not disassemble,
crush, puncture, short external contacts, dispose of in water or fire, or expose it
to temperatures higher than 60
°
C (140
°
F).
CAUTION:
To prevent damage to equipment or loss of information, make sure
that the server is powered down, all cables are disconnected from the back of
the server, and the power cord is disconnected from the grounded (earthed) AC
outlet before removing the access panel.
CAUTION:
Static electricity can damage electronic components of the server.
Before beginning these procedures, be sure that you are discharged of static
electricity by briefly touching a grounded (earthed) metal object.
The ProLiant ML350 Generation 2 has nonvolatile memory which requires
batteries to retain system information. There is a battery on the system board
and a battery on the Server Feature Board.