GS320 Assembly
3-9
Position system cabinet 1 at the predetermined location. Lower the corner
leveling feet on system cabinet 1 until the system cabinet is anchored and the
casters are free to rotate. Release the tie wraps on the CSB cable and hose
cables that are coiled and attached to the sides of system cabinets for later
routing.
Prepare system cabinet 1 for joining.
1.
Remove the left side panel
and top cover
.
2.
Remove system box rear covers (not shown) and hierarchical switch
(H-switch) covers
.
3.
Loosen the H-switch mounting screws and gently rotate the H-switch
toward system cabinet 1
.
4.
Remove the support pieces on the left side of the system cabinet, as well as
the fastening hardware
. These pieces will not be reinstalled.
5.
Remove the two labels that cover the lower alignment holes
.
NOTE:
If you are upgrading a single-system box system with a distribution
board attached to system cabinet 1, you must replace the distribution
board with a hierarchical switch. Procedures for the removal of the
distribution board and the installation of the hierarchical switch are
given in the AlphaServer GS160/320 Upgrade Manual.