StorageWorks Fibre Channel Storage Switch User's Guide
E_D_TOV
Pressing <Enter>, while
E_D_TOV
is selected, displays:
E_D_TOV
2000
E_D_TOV (Error Detect Time Out Value) is adjustable in 1-second
increments using the front panel controls, but its value is displayed in
milliseconds.
NOTE: Use the flashSet command during a Telnet session to set the E_D_TOV or
R_A_TOV value (in milliseconds) for values other than whole seconds.
This timer is used to flag a potential error condition when an expected
response is not received (an acknowledgment or reply in response to packet
receipt, for example) within the set time limit. If the time for an expected
response exceeds the set value, then an error condition is met. The range is 1
to 60 seconds.
NOTE: The set value must be less than the set value for the Resource Allocation Time Out
Value.
Operating Mode
Pressing <Enter>, while
Operating Mode
is selected, displays:
Operating Mode:
0