6.16 Rate Limiting
You can set up every port’s frame limitation type and bandwidth rate.
Rate Limiting interface
!
Ingress Limit Frame type:
Select the frame type you want to filter. The frame types
have 4 options for selecting:
All,
Broadcast/Multicast/Flooded Unicast,
Broadcast/Multicast,
and
Broadcast only
.
The four frame type options are for ingress frames limitation. The egress rate only
supports ‘
All
’ type.
!
All the ports support port ingress and egress rate control. For example, assume port
1 is 10Mbps; the user can set the effective egress rate of port 1 as 1Mbps, ingress
rate 500Kbps. The switch performs the ingress rate by packet counter to meet the
specified rate.
"