INS_CNXE2GE2TX8MSPOE 11 Jan 2021 PAGE 44
INSTALLATION AND OPERATION MANUAL
CNXE2GE2TX8MSPOE
TECH SUPPORT: 1.888.678.9427
6.1.3 Users
Configuration
An overview of the current users. Currently the only way to login as another user on the web
server is to close and reopen the browser.
Label
Description
User Name
A string identifying the user name that this entry should belong to. The allowed
string length is 1 to 31. The valid user name can be letters, numbers and
underscores.
Password
The password of the user. The allowed string length is 0 to 31.
Any printable characters including space are accepted.
Privilege Level
The privilege level of the user. The allowed range is 0 to 15. If the privilege level
value is 15, it can access all groups, i.e. that is granted the fully control of the
device. But other values need to refer to each group privilege level. User’s privilege
should be the same or greater than the group privilege level to have the access of
that group. By default, the group privilege level of 5 has the read-only access and
the privilege level of 10 has the read-write access. System maintenance (software
upload, factory defaults and etc.) requires the user privilege level of 15. Generally,
the privilege level of 15 can be used for an administrator account, privilege level 10
for a standard user account and privilege level 5 for a guest account.