![CommScope Ruckus ICX 7750 Hardware Installation Manual Download Page 76](http://html1.mh-extra.com/html/commscope/ruckus-icx-7750/ruckus-icx-7750_hardware-installation-manual_2643846076.webp)
74
Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Ruckus ICX 7750 Specifications
LEDs
LEDs
Other
Weight and physical dimensions
Environmental requirements
System component
Description
Switch status and management
Nine LED states to indicate switch and module status (green and amber)
Port status
Five LED states to indicate port status (green and amber)
System component
Description
Serial cable
Mini-USB to RJ-45
RJ-45 to DB9 adapter
1
Stack Control-Path Cable
Two Micro-HDMI to RJ-45 (currently not used)
Control-Path Cable Holder Kit
One cable holder and one screw
Model
Height
Width
Depth
Empty weight
Fully loaded weight
ICX 7750-26Q
4.37 cm
1.72 in
44.00 cm
17.32 in
40.64 cm
16.00 in
5.60 kg
12.30 lb
8.80 kg
19.40 lb
ICX 7750-48F
4.37 cm
1.72 in
44.00 cm
17.32 in
40.64 cm
16.00 in
5.90 kg
13.00 lb
9.10 kg
20.10 lb
ICX 7750-48C
4.37 cm
1.72 in
44.00 cm
17.32 in
43.10 cm
16.97 in
7.00 kg
15.40 lb
10.20 kg
22.50 lb
Condition
Operational
Non-operational
Ambient temperature
ICX 7750-26Q: -5º to 50ºC (23º to 122ºF)
ICX 7750-48F: -5º to 50ºC (23º to 122ºF)
ICX 7750-48C: -5º to 40ºC (23º to 104ºF)
-40º to 60ºC (-40º to 140ºF)
Relative humidity (non-condensing)
ICX 7750-26Q and ICX 7750-48F:
10% to 90% at 50ºC (122ºF)
ICX 7750-48C:
10% to 90% at 40ºC (104ºF)
10% to 90% at 60ºC (140ºF)
Altitude (above sea level)
0 to 3000 m (10,000 feet)
12,000 m (39,000 feet)
Shock
20 G, 11 ms, half-sine wave
30 G, 11 ms, half-sine wave
Vibration
1 G sine, 0.4 grms random, 5-500 Hz
2.4 G sine, 1.12 grms random, 5-500 Hz