![CommScope Ruckus ICX 7750 Hardware Installation Manual Download Page 19](http://html1.mh-extra.com/html/commscope/ruckus-icx-7750/ruckus-icx-7750_hardware-installation-manual_2643846019.webp)
Ruckus ICX 7750 Switch Hardware Installation Guide
17
Part Number: 53-1003900-10
Ruckus ICX 7750 Overview
Supported transceivers and cables
The 40 GbE BiDi transceivers enable 40 GbE links to be supported on installed 10 GbE duplex fiber infrastructure. This optic has the
same port limitations as the LR4 optic.
Breakout cables
The Ruckus ICX 7750 can support the following breakout cables on certain 40 GbE ports:
•
QSFP+ to 4 SFP+ (4x10 GbE) direct-attach copper breakout cables, lengths of 1, 3, and 5 m
•
4x10 GbE QSFP+ SR4 compatible with 10GBase-SR SFP+ using 1, 2, 3, 5, 7, 10, 15, and 100 m lengths of fiber cable
FIGURE 10
QSFP+ to 4 SFP+ (4x10 GbE) breakout cable
The Ruckus ICX 7750 ports available for breakout are shown for each model in
QSFP+ to SFP+ adapter support
The Ruckus ICX 7750 supports a third-party QSFP+ to SFP+ adapter for cost-effective connections between 40 GbE QSFP+ ports and
10 GbE hardware using standard SFP+ optical cabling rather than breakout cables.
An SFP+ transceiver (SR, LR, or USR) inserted in the QSFP+ to SFP+ adapter behaves as if it is connected to the first of the 4 breakout
ports on the 40 GbE QSFP+ interface with no other ports available in the breakout. The 4x10 GbE breakout mode must be configured on
the QSFP+ interface.
10G-SFPP-TX-A transceiver support
The 10G-SFPP-TX-A transceiver consumes significantly more power than typical 10G transceivers. This section provides guidelines for
deploying the 10G-SFPP-TX-A transceiver within the power capabilities of the supported ICX 7750-48F switch.
If the guidelines in this section are not followed, there is a risk of system instability and/or reboot.
Follow the guidelines provided in
For each 10G-SFPP-TX-A installed, another SFP+ slot MUST be left empty.
TABLE 6
Ruckus ICX 7750 40 GbE breakout ports
Model
Front panel Slot 1 ports
Front panel Slot 2 ports
Rear module Slot 3 ports
ICX 7750-26Q
1/1/5 through 1/1/16
1/2/1 through 1/2/6
1/3/1 through 1/3/6
ICX 7750-48F
N/A
1/2/1 through 1/2/6
1/3/1 through 1/3/6
ICX 7750-48C
N/A
1/2/1 through 1/2/6
1/3/1 through 1/3/6