Chapter 5
Configuring the OneCell system
OneCell
®
Installation and Commissioning, RP5000 series, Release 4.0
5-21
D
R
A
F
T
BC State
•
Active – Active member of the cluster
•
StandBy – StandBy member of the cluster
Virtual Cell ID
A unique ID used to tie LTE service parameters together on a
Baseband Controller running in Active mode in a cluster.
Note:
This field is mandatory if Active State is selected.
Operator Configuration – Security Gateway 1 Configuration
Security Gateway FQDN/IP
Address
The Baseband Controller establishes a secure tunnel connection
with this gateway for S1 or OAM traffic.
IP address <A.B.C.D> or FQDN
Address Type
•
Static – When set to Static, the user/operator should define a
static Tunnel Inner Address for the S1 tunnel
•
Dynamic – When configured Dynamic - the address is
dynamically assigned by the Security Gateway during IKE
processing
Tunnel Inner Address
Tunnel IP Address provided by the Security Gateway after
successful session establishment
<A.B.C.D>
Tunnel CIDR
CIDR format [1 - 32]
Tunnel Internal DNS
IP Address <A.B.C.D>
Exclude Configuration Payload
(CP)
•
True – Configuration Payload is excluded during IKE
processing.
•
False – Configuration Payload is included during IKE
processing.
Operator Configuration – Security Gateway 2 Configuration
Security Gateway FQDN/IP
Address
The Baseband Controller establishes a secure tunnel connection
with this gateway for S1 or OAM traffic.
IP address <A.B.C.D> or FQDN
Address Type
•
Static – When set to Static, the user/operator should define a
static Tunnel Inner Address for the S1 tunnel
•
Dynamic – When configured Dynamic - the address is
dynamically assigned by the Security Gateway during IKE
processing
Tunnel Inner Address
Tunnel IP Address provided by the Security Gateway after
successful session establishment
<A.B.C.D>
Tunnel CIDR
CIDR format [1 - 32]
Table 5-2. Baseband Controller operator parameters, configuration file
Parameter
Description
Summary of Contents for OneCell RP5100i
Page 7: ...Contents OneCell Installation and Commissioning RP5000 series Release 4 0 vii DRAFT ...
Page 10: ...List of tables x 913035 4 0 04 June 2019 DRAFT ...
Page 12: ...Document revision history xii 913035 4 0 04 June 2019 DRAFT ...
Page 18: ...About this document xviii 913035 4 0 04 June 2019 DRAFT ...
Page 20: ...DRAFT ...
Page 28: ...DRAFT ...
Page 68: ...Chapter 4 RP5100i installation 4 32 913035 4 0 04 June 2019 DRAFT Installation is complete ...
Page 69: ...DRAFT Part III Commissioning Chapter 5 Configuring the OneCell system ...
Page 70: ...DRAFT ...