Configuration via Web Interface
Commend SIP Series
40
2.0/0612
Registration max. Expires:
Here the timer is set, which is responsible for the update of the regis-
tration of the station at the SIP server. I.e. the entered time in seconds is sent by the SIP station to
the SIP server (
Proxy
see below
). The server is sending an acknowledge or alternate time interval
back, which will then be set and used immediately. I.e. within this time interval the registration of the
SIP station at the SIP server will be updated regularly.
Server Settings
In the section
Primary Server
, settings required for the connection to a SIP server, have to be confi-
gured.
Registration Enabled:
If this checkbox is activated, the SIP station tries to register (with the appro-
priate
User
and
Password
) at the SIP server specified at
Proxy
(see below).
User:
The call number of the SIP station for the SIP registration has to be entered, i.e. the call
number of the corresponding SIP account on the SIP server.
Password:
The corresponding password (defined at the SIP server) for the SIP registration has to
be entered (required for authentication).
Proxy:
The IP address or URL of the appropriate SIP server to which a connection shall be establis-
hed (i.e. at which the SIP station shall be registered).
Additional Server
In the section
Secondary Server
, a connection to an additional SIP server can be configured. Thus a
better reliability of the appropriate SIP station is achieved (e.g. if the connection to the primary server
is lost, the SIP station can still be reached via the secondary server).
Secondary Server Enabled:
With activation of this checkbox, the connection to a second server is
enabled. I.e. the SIP station tries to register (with the respective
User
and
Password
) at the SIP ser-
ver, which is entered at
Proxy
.
User / Password / Proxy
:
see above
Call Settings
In this section, the settings required for establishing a call, have to be configured.
Answer Call:
Combo-box for configuration of the call acceptance.
Menu items:
Autoanswer
: An incoming call is accepted without any ringing and without pressing any button.
Button
<x>
: The call is not accepted until the corresponding button of the SIP station is pressed.
Any Button:
The call can be accepted via pressing any button of the SIP station (however it has
to be pressed one button).
Cancel Call:
Combo-box for configuration of how a running conversation (between two SIP de-
vices) shall be cancelled.
Standard: 3600 sec.
Note:
The registration is updated 60 seconds before the timer expires (but not less than 40 seconds).
Note:
In case of operation without server, this checkbox has to be deactivated.
Note:
For some SIP servers it may be required to enter additionally the domain
“user name@domain”.
Note:
The number and the labelling of the buttons in the drop-down menu depends on the used station ver-
sion (
see page 10
) and the number of configured direct dialling modules in use (
see page 49
).