1/2/02
ALA550
5
85
86
87
87a
30
Pink wire
To horn
+ 12 V
+12V Or Ground
Depending On
System Requirements
HORN
FUSE
87a
86
87
30
85
Fuse
Pink Wire
+12V Or Ground
Depending On
System Requirements
+12V
Electric Device
CHANNEL 3
H7/9 . GRAY WIRE – (-) 200mA TIMER CONTROL CHANNEL 2 / PAGER OUTPUT –
TIMER CONTROL CHANNEL 2 OUTPUT (Factory default setting on 1 second pulse grounded)
This will become a 1 second pulse ground by activate channel 2 on transmitter for two seconds, the
current capacity of this wire is 200mA. This feature allow you to remote control trunk release or other
electric device. This output can also be programmed to provide the following type of output: 1 second
pulse, latched, timer control and pager. (See Alarm Feature
III - 3
Programming)
PAGER OUTPUT
(
See Feature
III – 3
Programming)
This wire provides a negative output, when the alarm triggered. The current capacity of this wire is
200mA. For optional electrical device in this system, please connected to an additional relay. (I.E. Pager
interface....)
87a
86
87
30
85
Fuse
Gray Wire
+12V Or Ground
Depending On
System Requirements
+12V
Electric Device
CHANNEL 2 /
TRUNK
87a
86
87
30
85
Fuse
Gray Wire
+12 V
Pager
Power Wire
PAGER
H7/10. WHITE WIRE – (-) 200mA DOME LIGHT CONTROL OUTPUT –
This wire becomes grounded when the dome light control circuit active. The current capacity of this wire
is 200mA. This wire can control the operation of the interior light . An optional 10 Amp relay can be used to
this system for interior light operation.
a). Upon disarming, the interior lights will remain on for 30 seconds.
b). If the vehicle is violated, the interior light will flash for the same duration as the siren.
87a
86
87
30
85
Fuse
White Wire
+12V
Domelight
Door
Switch
Courtesy
Light
H4. 3 PIN DOOR LOCK HARNESS:
Blue
Wire
Green
Wire
( - ) Lock Pulse
( + ) Unlock Pulse
( - ) Unlock Pulse
(+) Lock Pulse
INSTALL NEW DOOR LOCK MOTOR
Blue Wire
Green
+12V
30
86
87a
85
87
30
86
87a
85
87
3 Pin
Plug To
Alarm