15
I TIME: set idle action time, the time can be selected: 1-255 mins. The default idle time is one minute.
II ACTION TYPE: this option is to set the type of idle action. Presets, linear scan, cruise scan, pattern scan, group scan,
continuous scan and interval scan optional, default is no action. The PTZ camera executes idle actions without receiving valid
commands during the set idle time.
III ACTION NUM : this item selects the number of the action type for the above action type. When the selected item is "---", the
current action type has no optional number, that is, the current action number cannot be set.
③
PROPORTIONAL: on and off optional, default is on.
④
AUTO FLIP :on or off, default is on. When set to open, the operator pulls the lens to the bottom (vertical) and then holds the
rocker. At this time, the lens automatically rotates 180 degrees horizontally and then flips 90 degrees upward. It can directly see the
scenery on the back, thus realizing the continuous monitoring of 180 degrees longitudinally.
⑤
Horizontal reverse: on or off, default
is off. When set to open, the rocker left and right movement command will carry out direction processing, that is, the original right
movement command will become the left movement command, and the left movement command will become the right movement
command.
⑤
HM SPEED:Manual operation speed: 1-10 level optional, default speed is 10 level. Level 1 is the lowest speed for manual
operation, and level 10 is the highest speed for manual operation.
1.2.5 ADDR SETTING
In Figure 1-2-1, move the rocker up and down so that the cursor points to the PTZ camera addr setting, and then move the
rocker to the right to enter the PTZ camera addr setting menu. As shown in Figure 1-2-5.
Figure 1-2-5
①
ADDR HARD: default is 0.
②
ADDR TYPE : default is SOFT.
③
ADDR SOFT: 0-255 optional, default is 0.
1.2.6 ALARM SETTING
I
n Figure 1-2-1, move the rocker up and down so that the cursor points to the alarm setting, and then move the rocker to the right
to enter the alarm setting menu. As shown in Figure 1-2-6.
ADDR SETTING
ADDR HARD 0
ADDR TYPE SOFT
ADDR SOFT 0
BACK
EXIT