Comelit 8451V Technical Manual Download Page 20

20

MNVK/040QC

8451V

C

F

P

L

L

C

F

P

1

2

L

L

O

D

E

T

R

NO

SE

-

SE

+ NC

C

M

O

C

1209

L

N

110-240V

L2
L2
L1
L1

4893M

LM

LM

OUT

L

IN

L

IN

L

OUT

L

1214/2C

LM

LM

OUT

L

IN

L

IN

L

OUT

L

1214/2C

C

F

P

L

L

C

F

P

1

2

L

L

1216

6721W
6721W/BM  +6710

6741W

6741W/BM +6710

Address

Address

ON

8

5 7

6

4

3

2

1

1234 67

5

8

ON

S1

S2

ON

8

5 7

6

4

3

2

1

1234 67

5

8

ON

S1

S2

IT

EN

FR

NL

DE

ES

PT

IT

NL

ES

PT

EN

FR

DE

Espansione per impianto bifamiliare

#

 

Per programmare la funzione speciale “pulsanti 1-2 attivi con indirizzi di 

chiamata 1-2”, vedi pag 13.

 Pulsante comando apriporta locale.
 I monitor supplementari art. 6721W/BM non includono la staffa.

Expansion for two-family system

#

 

To program the special function “buttons 1-2 enabled with call addresses 1-2” 

see page 13.

 Local lock release button.
 Additional monitors art. 6721W/BM do not include a backplate

Évolution pour installation deux appels

#

 

Pour programmer la fonction spéciale « boutons 1-2 actifs avec adresses d’appel 

1-2 », voir page 13.

 Bouton ouvre-porte sortie.

    Les moniteurs supplémentaires art. 6721W/BM ne sont pas équipés de l’étrier.

Uitbreiding voor tweevoudige installatie

#

 

Raadpleeg voor het programmeren van de speciale functie “drukknoppen 1-2 

actief met oproepadressen 1-2”

,

 zie pag. 13

 Lokale bedieningsknop deuropener.
 De extra monitoren art. 6721W/BM zijn exclusief muurplaat.

Erweiterung für Zweiteilnehmerinstallation

#

 

Für die Programmierung der Sonderfunktion “Tasten 1-2 aktiviert mit  mit 

Rufadressen 1-2”  siehe Seite 13.

 Taste lokaler Türöffner.
 Die Zusatzmonitore art. 6721W/BM schließen nicht die Grundplatte ein.

Expansión para instalación bifamiliar

#

 

Para programar la función especial “pulsadores 1-2 activados con direcciones 

de llamada 1-2” véase la pág. 13.

 Pulsador abrepuertas local.
 Los monitores adicionales arts. 6721W/BM no incluyen la placa soporte.

#

 

Para programar a função especial “botões 1-2 activos com endereços de 

chamada 1-2”, consultar a página 13.

 Botão de comando de abertura da porta local.
 Os monitores adicionais art. 6721W/BMnão incluem o suporte.

Expansão para equipamento bifamiliar

www.gomezmorenomaterialelectrico.com [email protected] 952 477 720

Summary of Contents for 8451V

Page 1: ...V Art 8451V BM Single family kit Art 8451V Art 8451V BM Kit un appel Art 8451V Art 8451V BM Enkelvoudige installatieKIT Art 8451V Art 8451V BM Kit Einteilnehmerinstallation Art 8451V Art 8451V BM Kit...

Page 2: ...uitend door gespecialiseerde elektriciens worden verricht Sluit de voeding af voordat u onderhoudswerkzaamheden uitvoert Installeer de camera niet tegenover felle lichtbronnen of op plaatsen waar de o...

Page 3: ...ncipale e 1 posto esterno secondario Operation Fonctionnement Werking Funktionsweise Funcionamiento Funcionamento EN To make a call from an external unit To send the call from an external unit touch t...

Page 4: ...installer seulement 1 poste ext rieur principal et 1 poste ext rieur secondaire NL Een oproep vanaf het deurstation uitvoeren Raak vanaf het deurstation de drukknop aan die overeenkomt met de gebruike...

Page 5: ...lieren ES Efectuar una llamada desde la placa externa Desde la placa externa tocar el pulsador correspondiente al usuario que se desea contactar para enviar la llamada Si la instalaci n est libre en l...

Page 6: ...e intercomunica o Neste caso os utilizadores que estiverem em comunica o ouvir o um som semelhante ao som de chamada se a chamada lhes for dirigida ou ent o tr s sons e surgir o v deo do posto externo...

Page 7: ...ng van het toestel kan afsluiten Netzteil art 1209 1 L N eingang Netzspannung 110 240 V 2 Klemmenschutz 3 L1 L1 ingang Haupt Busleitung 31 V 4 L2 L2 bus Steigleitung 31 V Die elektrische Anlage des Ge...

Page 8: ...ate in response to a call can be disabled by setting DIP 7 to ON see page 12 3 Wide angle colour camera 4 Loudspeaker 5 Indicator LED call sent lock release enabled audio enabled system engaged 6 Call...

Page 9: ...hverbindung 13 Klemmenleiste M2 SE SE Anschluss f r elektrisches T rschloss NC ffnungskontakt des Relais NO Schlie kontakt des Relais C Gemeinsamer Kontakt des Relais 14 JP1 Freigabe des RC Netzes f r...

Page 10: ...osas ni en lugares donde la persona captada quede en contraluz En ambientes poco iluminados se aconseja instalar una fuente de iluminaci n adicional A c mara n o deve ser instalada frente de fontes de...

Page 11: ...die u in onze catalogus vindt art 1217A NL Verzeker u er voordat u de schroef vastzet van dat het deurstation niet hoeft te worden geprogrammeerd zie pag 12 13 en verzeker u ervan dat het metalen fron...

Page 12: ...Envio chamada tripla Invio chiamata singola Call transmission single Envoi appel simple Oproep verzenden enkelvoudig Ruf bermittlung Einzelruf Env o de llamada nico Envio de chamada nica DIP 6 toni di...

Page 13: ...8 Ripristino default Restore default R tablissement r glage d usine Reset default Reset auf Voreinstellung Restablecimiento predefinido Repor predefini o IT Programmazione indirizzo di chiamata per 2...

Page 14: ...ge management Default ON Do not change DIP 8 not used 9 10 Factory setting Do not change 11 CV 5 Jumper for video closure 12 Pin for securing terminal block 13 S3 Microswitches DIP 1 operating mode De...

Page 15: ...uss an die Anlage LL Anschlussklemmen BUS Leitung CFP1 CFP2 Eingang Au ensprechstelle Configurar el c digo de usuario mediante los DIP switches de S1 1 Regulaci n del brillo 2 Regulaci n del volumen d...

Page 16: ...nitors op het toestel de goede ontvangst van het WiFi signaal de afstand tussen router en monitor de dikte en het materiaal van de wanden kunnen de kwaliteit van het signaal be nvloeden Antes da insta...

Page 17: ...o c maras separadas com endere o 221 CCP Chiamata a centralino principale Main switchboard call Appel standard principal Bellen naar hoofcentrale Ruf an Haupt Pf rtnerzentrale Llamada a la centralita...

Page 18: ...nterno principale e max 3 posti interni secondari EN The total number of internal units with the same user code and call repetition devices Art 1229A cannot exceed 4 with a maximum of 1 main internal...

Page 19: ...16 monitors art 1229A max EN Standard single family system Switching on voltage check with system in standby Local lock release button UTP cable with multi cable connection FOLLOW THE COLOURS SHOWN I...

Page 20: ...porte sortie Les moniteurs suppl mentaires art 6721W BM ne sont pas quip s de l trier Uitbreiding voor tweevoudige installatie Raadpleeg voor het programmeren van de speciale functie drukknoppen 1 2...

Page 21: ...ndaires compatibles voir page 18 Bouton ouvre porte sortie Pour programmer la fonction sp ciale boutons 1 2 3 4 actifs avec adresses d appel 1 2 3 4 voir page 13 Uitbreiding voor systeem met 4 gebruik...

Page 22: ...ede deurstation 4893M en deurselector art 1405 Raadpleeg voor het programmeren van de speciale functies Hoofddeurstation Hoofdspeakerunit en Secundair deurstation Secundaire speakerunit zie pag 13 Lok...

Page 23: ...di chiamata Connection diagram for two family system with one main monitor and 2 secondary monitors cascade connection Connection diagram for system with maximum expansion in branch connection for sin...

Page 24: ...gaan dan tegelijk over Variant met veiligheidsslot en extra voeding 20 m MAX Gebruik een afgeschermde kabel voor deze verbinding en leid de kabels niet in de nabijheid van hoge inductieve belastingen...

Reviews: