To re-stitch the scanner manually, first carefully examine the scan of the Manual Stitch Target. It may be more
efficient for example to alter the values at just a single sensor intersection rather than altering the values at three!
F/B adjustment
Make alterations to restore a horizontal line at all sensor intersections. For example to correct a rising F/B stitch at
boundary 1-2 lower the value in CIS 2 (reduce 4 to 2). Note that this will improve the falling stitch at boundary 2-3. After
making single or multiple corrections click „Set Stitch‟ to save the setting(s) into scanner calibration memory. Rescan
the Manual Stitch Target, re-inspect and make further adjustments as required.
L/R adjustment
Make alterations to restore a diagonal line at all sensor intersections. For example to correct a rising L/R stitch at
boundary 1-2 increase the value in CIS 1. Note that because CIS 2 is high relative to CIS 3 it might be more efficient to
reduce the value in CIS 2. After making single or multiple corrections click „Set Stitch‟ to save the setting(s) into scanner
calibration memory. Rescan the Manual Stitch Target, re-inspect and make further adjustments as required.
When you are satisfied that you have re-stitched the scanner exit from the Ci Utilities program and re-check using
SmartLF All-In-One or ScanWorks.
CIS #1
CIS #2
CIS #3
CIS #4
CIS #5
Stitch 1-2
Stitch 2-3
CIS #1
CIS #2
CIS #3
CIS #4
CIS #5
Stitch 1-2
Stitch 2-3