INSTALLATION & USER'S MANUAL CLITE2
Page 61
Category 2: Diagnostics (support tool)
16.3
In this chapter all of Category 2 menu items will be explained.
(2.1) Start
16.3.1
Press the OK button to run the on-board diagnostic test suite to sense the electrical and
mechanical condition of the searchlight. (contact Colorlight for help with this feature).
T1
. Measurement of voltage an
d current when the searchlight is in “non operating mode”
T2 (HCW).
Measurement of current drawn by the horizontal motor; motor rotates clockwise for
30 seconds.
T3 (HCCW).
Measurement of current drawn by the horizontal motor; motor rotates
counterclockwise for 30 seconds.
T4 (VCW).
Measurement of current drawn by the vertical motor; motor rotates clockwise for 30
seconds.
T5 (VCCW).
Measurement of current drawn by the vertical motor; motor rotates
counterclockwise for 30 seconds and the value is temporary stored.
T6 /T7 (not valid for this model).
T8 (H MAG).
Test of horizontal magnetic sensor; the horizontal motor is running at full speed for
a predetermined time and number of triggers is recorded.
T9 (V MAG).
Test of vertical magnetic sensor; the vertical motor is running at full speed for a
predetermined time and number of triggers is recorded.
T10 (Lights).
LED-module test; both lights should ignite and be lit for 30 seconds.
LED modules provide no feedback to to the Ebox and the test result for
T10
will always show
"OK", therefore this light test must be visually verified to ensure that the LED modules light up.
T11 (OP count).
Counting the number of connected operator terminals in the network.
(2.2) View Results
16.3.2
Displays the result of the last run diagnostics test suite.
Use the
“
Down
” button to cycle through the tests results.
Use the
“
Right
” button to cycle through different test result information for the selected test.
Only applicable for test “T1” and test “T10”.
Summary of Contents for CLITE2
Page 57: ...INSTALLATION USER S MANUAL CLITE2 Page 57 OP Rotation illustration 270 0 90 180...
Page 66: ...Page 66 INSTALLATION USER S MANUAL CLITE2 Mechanical drawings 17 2 Operator Panel 17 2 1...
Page 67: ...INSTALLATION USER S MANUAL CLITE2 Page 67 Electrical box CLITE2 100 240VAC 17 2 2...
Page 68: ...Page 68 INSTALLATION USER S MANUAL CLITE2 Electrical box CLITE2 24VDC 17 2 3...
Page 74: ...Page 74 INSTALLATION USER S MANUAL CLITE2 CLITE2IR VIDEO CONNECTION 19...
Page 86: ...Page 86 INSTALLATION USER S MANUAL CLITE2...