INSTALLATION & USER'S MANUAL CLITE2
ACTIONS AFTER INSTALLATION AND POWER FAILURE
10.
At system startup, the panels will start to scan the network to find connected electrical boxes,
during this time, the panel software version will be displayed.
If not the panel made contact by displaying home screen within 30 seconds, it may be due to
the following:
Electrical box is not turned on, applies only if the panel has a separate power supply.
There are problems in the network cabling between the electrical box and the operator
panel.
Automatic recovery of stored searchlight position in panel.
10.1
A new feature was introduced with the release of the control software,
v 0.5.23.35
for ebox and
v 0.6.0.7
for the operator panels, from these versions this is a standard feature*.
With this new feature the system always stores the searchlight position after the movement has
been idle for 20 seconds. The position is stored in in a non-volatile memory.
When the system is restarted after power loss, the last stored position will automatically be
reloaded in to the panel.
The panel position indicator differs from the actual position of the
10.1.1
searchlight.
At boot up, the panel position indicator can differ from the searchlight actual position for the
following reasons:
The system power was interrupted in the middle of a joystick maneuver.
The searchlight had just been maneuvered but the power interruption occurred before
the 20 seconds elapsed and therefore the new position was not stored.
The searchlight axis has turned away from latest stored position while it was switched
off, manually or by wind gusts.
Positional deviations depending on the above will be automatically corrected when the
next
“Park” is commanded.
Note:
always synchronize before setting sweep*, fixed positions* or surveillance* to ensure that
the system is not rebooted with deviating positions, please see
*
Older systems can be updated, please contact us for more information
.
Summary of Contents for CLITE2
Page 57: ...INSTALLATION USER S MANUAL CLITE2 Page 57 OP Rotation illustration 270 0 90 180...
Page 66: ...Page 66 INSTALLATION USER S MANUAL CLITE2 Mechanical drawings 17 2 Operator Panel 17 2 1...
Page 67: ...INSTALLATION USER S MANUAL CLITE2 Page 67 Electrical box CLITE2 100 240VAC 17 2 2...
Page 68: ...Page 68 INSTALLATION USER S MANUAL CLITE2 Electrical box CLITE2 24VDC 17 2 3...
Page 74: ...Page 74 INSTALLATION USER S MANUAL CLITE2 CLITE2IR VIDEO CONNECTION 19...
Page 86: ...Page 86 INSTALLATION USER S MANUAL CLITE2...