Mounting Configurations
Perform the following steps to change between the in-line and right-angle configuration.
Note
:
l
Switching between the in-line and right-angle configuration is recommended only up to 10 times in the
lifetime of the vision sensor.
l
You can order a replacement kit (IS2000-CAPS-KIT) if you misplaced screws, washers or caps.
CAUTION
:
Make sure that no electrostatic charges are applied to the PCB (e.g., wear ESD shoes). If the main
module is separated from the I/O connector module, make sure to reassemble them correctly. Otherwise, the IP
rating can be compromised.
1. Verify that the 24VDC power supply is unplugged and not receiving power.
2. Carefully remove the screw covers, threaded cap nuts and washers.
3. Detach the main module and the I/O connector module by firmly pulling them apart.
4. Change the orientation.
26
Installation