36
37
1
2
3
4
5
6
7
8
12
11
10
9
24 VDC
+
–
24 VDC
+
–
24 VDC
+
–
24 VDC
+
–
24 VDC
+
–
Power
Trigger (Checker sinks current)
Trigger (Checker sources current)
Outputs (Checker sinks current)
Outputs (Checker sources current)
24 VDC+ POWER IN (RED)
TRIGGER (ORANGE)
INPUT COMMON (WHITE/VIOLET)
OUTPUT 1 (GREY)
OUTPUT COMMON (GREEN)
GROUND (BLACK)
INPUT COMMON (WHITE/VIOLET)
TRIGGER (ORANGE)
OUTPUT 0 (BLUE)
OUTPUT 1 (GREY)
OUTPUT COMMON (GREEN)
OUTPUT 0 (BLUE)
Circuit Diagrams (Typical)
Input/Output Wiring
The leads in the flying lead cable (C3G-CBL-001) are color-coded to indicate which signal is
carried on which line The corresponding pins on the M12 connector are provided as well
Note:
Pin numbers for male connector
on Checker 3G are shown
When wiring Checker 3G, observe the following precautions:
Use a listed power supply with an output rated 24 VDC, at least 250 mA, and marked Class 2,
•
Limited Power Source (LPS). Any other voltage creates a risk of fire or shock and can damage
Checker
Connect the cable or connector shield to earth ground
•
Make sure that no voltage potential exists between the USB ground on the PC and the
•
Checker chassis ground
To reduce the risk of damage or malfunction, route all cables and wires away from high-
•
voltage power sources
Lead Color
Signal
M12 Pin
RED
24 VDC +
7
BLACK
24 VDC –
8
VIOLET
RETRAIN
5
YELLOW
JOB CHANGE
1
WHITE/YELLOW
JOB SELECT 0
2
BROWN
JOB SELECT 1
3
WHITE/BROWN
JOB SELECT 2
4
ORANGE
TRIGGER
10
WHITE/VIOLET
INPUT COMMON
6
BLUE
OUTPUT 0
11
GREY
OUTPUT 1
12
GREEN
OUTPUT COMMON
9
Summary of Contents for Checker 3G Series
Page 1: ...COGNEX Checker 3G Series User s Guide...