CAFÉ ELITE
36
Hardware Test
Canister 4 0
Hardware Test
Fan 0
Hardware Test
Heater 0
Hardware Test
LevelSens 0
Hardware Test
Mix Motor1 0
Hardware Test
Mix Motor2 0
Hardware Test
Tray Sensor 0
PROGRAMMING
E
E
E
E
E
Pressing ENTER will start/stop canister
motor 1
0 = motor off; 1= motor on
Pressing ENTER will start/stop the fan
0 = fan stopped;
200= fan at full speed
Shows current temperature in boiler
Heater XX
0
C
Show status of level sensors signal
0= Tank empty
1= Level low triggerd
3= Tank full
Pressing ENTER will will start/stop
mixer motor 1
0 = motor off;
200= motor at full speed
Pressing ENTER will will start/stop mixer
motor 1
0 = motor off;
200= motor at full speed
Connecting the springs together for the
drip tray sensor to change value
0= Drip tray not full
1= Drip tray full
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Summary of Contents for CAFE ELITE
Page 1: ...TM_EN Part No 1740056_02 CAFÉ ELITE TECHNICAL MANUAL ...
Page 40: ...CAFÉ ELITE 40 EXPLODEDVIEW Door Drawing 01 02 03 04 16 13 14 08 09 10 11 05 06 15 07 12 ...
Page 50: ...CAFÉ ELITE 50 EXPLODEDVIEW Canister Drawing 01 02 03 04 05 09 10 06 08 07 ...
Page 52: ...CAFÉ ELITE 52 CIRCUIT DIAGRAM High Current ...
Page 53: ...CAFÉ ELITE 53 CIRCUIT DIAGRAM High Current 3 phase ...
Page 54: ...CAFÉ ELITE 54 CIRCUIT DIAGRAM IO Board Outputs HOT WATER MIXER 2 ...
Page 55: ...CAFÉ ELITE 55 CIRCUIT DIAGRAM Ucmerisc and IO pay board ...