If the operating voltage and frequency as preset by
coemar
does not correspond to that of the country in which you are ope-
rating, you may alter the preset by following the instructions in the paragraphs which follow.
An error in voltage or frequency selection may seriously compromise the correct functioning of the
projector.
16.1 Selecting the voltage on the autotransformer
1) Remove the screws on the base of the fixture, as shown in the picture below, then simply lift the covers to access the
internal components of the
ProWash 575 LX.
2) Locate the autotransformer.
3) Select the tension among 115, 208, 230 and 240V
disconnetting cable n° 22 and moving it on the desired
tension. For a correct selection, refer to the label on the
autotransformer.
Cables n° 4,23, 24 e 25 should not be moved from their
position for any reason.
4) If the tension you chose is 115V replace the 8 Amps T
fuse ,ideal for a selection at 208/230/245 V, with a 15
Amps T one. the fuse holder is located on the base of
the fixture. You will find the replacement fuse in a pla-
stic bag attached to this present manual
5) Proceed now to select the frequency as described in the next paragraph, or replace the covers and close the base.
6) Cross on the label located on the baseof the
ProWash 575 LX
the tension you just selec-
ted, as shown in the picture on the following
page
T15A @115V
T8A @230V
16. Altering the operating voltage and frequency (Reserved for technical staff only)
21
English