![Coemar iWASH Halo Instruction Manual Download Page 7](http://html.mh-extra.com/html/coemar/iwash-halo/iwash-halo_instruction-manual_2634338007.webp)
5.1. Operating voltage and frequency
The projector may operate at voltages of 115, 208, 230 or 240VAC at a frequency of 50 or 60Hz.
Coemar
presets (barring specific
requests) a voltage of 230v at a frequency of 50Hz.. The preset voltage is indicated on the base of the projector.
5.2. Altering the operating voltage and frequency
(Reserved for technical personnel only)
If the factory preset operating voltage and frequency do not correspond to those in use in your country of operation, you may alter the
settings as described in the following paragraphs.
1.
Loosen the screws on the cover of the base of the unit, as shown in the
diagram below, using an appropriate screwdriver, thereby removing the
cover completely and allowing access to the internal components of the
base of the
iWash Halo
.
2.
Locate the transformer in the base of the unit.
3.
Select a voltage from amongst 115, 208, 230 or 240V by disconnecting
cable n° 5 and moving it to the correct voltage. Refer to the sticker locat-
ed on the transformer to ensure the proper terminal is selected for your
requriements.
Cable number 10 must not have its position altered under any cir-
cumstances
!
4.
If the voltage setting is 115V replace the fuses located on the rear pamnel
of the base. The fuse T2A, suitable for 208/230/240 V, must be replaced
with a fuse T3A, and the two fuses must be replaced by two fuses T15A.
The fuses are in a plastic envelope together with this instruction manual.
5.
When you have made changes, note these on the outside of the
iWash Halo
.
6.
Replace and fasten all the housings as per their original positions.
ATTENTION!!
Incorrect selection of operating voltage and frequency will seriously compromise the
functioning of the projector and will immediately void the warranty.
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
5. Powering up
7
English