Instructions to assemble and install
Edition E0
Page 41 of 69
Confidential and Property of CoeLux S.r.l.
Fig. 37
Installation of the ventilation kit
Once you have mounted the entire piece of equipment, use the M4 screws [43] (PN 33-00008-01)
supplied and proceed to install the manifolds. Now, cut the insulated pipe (PN 36-00022-01) into
2 equal parts, each measuring 2 metres [48], and use the hose clips [49] (PN 36-00023-01) to
connect them to the round manifold terminals. Once you have installed the entire equipment and
created the false ceiling, connect the two free ends of the insulated pipes to the latter (using
outlet valves) in order to enable the air to circulate with the room.
Fig. 38
Installation of the ventilation kit
48
49
42
43
36