background image

A1 
LACK OF WATER

A2 
LEVEL

A3 
TRANSDUCER

A4 
OVERCURRENT

A5 
PUMP OFF

A6 
ACCUMULATION

E

N

EN

6

10. ALERTS .

A1: LACK OF WATER ALERT.

n

 Warning:

 

Failure verification: LED LIGHT FAILURE FLASHING.

Final failure: LED LIGHT FAILURE ON.

n

 Description:

 if 

ONEMATIC 

detects lack of water in the inlet of the automatic control unit for more than 10 seconds, it will stop the pump 

and the ART will be triggered. 

n

 System reaction: 

after 5 minutes ART system will restart the pump for 30 seconds, trying to restore the system. In case of persisting  

lack of water, it will attempt another restart every 30 minutes for 24 hours. If, after repeat attempts, the system still detects a lack of water, 
the pump will be permanently stopped until the damage is repaired.

n

 Solution:

 there is a lack of water in the inlet, which resulted in the safety system to be triggered: verify the supply from the hydraulic 

network. The pump can be primed using the push-button 

START/STOP

 ( the 

AUTO On/off

 LED light should be off; if not, press the 

push-button to disable

 it).

A2: LEVEL SENSOR ALERT.

n

 Warning:

 

Final failure: LED LIGHT FAILURE ON.

n

 Description:

 if a float switch is installed in the inlet tank, it will inmediately stop the pump when it detects a lack of water.The system will 

show the message for lack of water.

n

 System reaction: 

the

 

pump will remain stopped until level sensor detects water in the tank.

n

 Solution:

 check tank.

A3: TRANSDUCER DAMAGED ALERT.

n

 Warning:

Final failure: LED LIGHT FAILURE ON.

n

 Description: 

transducer damage is displayed on the  

ONEMATIC

´s LCD screen.  Contact  the technical service when this alert was 

triggered.

n

 System reaction: 

unit operation is interrupted.

n

 Solution:

 contact with technical service.

A4: OVER-CURRENT ALERT.

n

 Warning: 

Failure verification: LED LIGHT FAILURE FLASHING.

Final failure: LED LIGHT FAILURE ON.

                      

n

 Description: 

the

 

pump is protected against over-current depending on the current value defined in the configuration menu. These over-

currents are  generally caused by malfunctions of the pump or in the electric supply.

n

 System reaction: 

when a failure is detected, the system will attempt to restart the pump four times. If the pump is still tripped after the 4th 

attempt, it will be switched off  until the damage is repaired.

n

 Solution: 

check the state of the pump; for example, the impeller could be blocked. Verify the current value entered in the configuration menu ( 

it is always recommended to define current values as 15% above the rated pump current). Check for damaged fuses. Once the possible 
problems have been solved, the pump is put back into operation; then, the "INSTALLATION" menu (see   chapter configuration) is 
displayed for entering the adequate current values.  

A5: DISCONNECTED PUMP ALERT.

n

  Warning:

Final failure: LED LIGHT FAILURE ON.

n

 Description: ONEMATIC

 cannot detect current from the pump and has disconnected the same to avoid severe damaging. There are 

three 10 A  fuses. In case of pumps with different consumption values,  suitable fuses must be chosen.

n

 System reaction:  

the system will remain off until the problem is solved externally.

n

 Solution: 

check the state of the fuses and replace as necessary. The winding of the motor and the pump consumption should also be 

checked. Once the possible problems have been solved, the pump is put back into operation; then, the “INSTALLATION” menu (see 
chapter Configuration)  is displayed for entering the adequate current values.  

A6: ACCUMULATOR  ALERT.

n

 Warning:

Final failure: LED LIGHT FAILURE ON.

n

 Description: 

the system  periodically analyses the state of the accumulator of the  hydraulic installation, however only in pressure -dependent 

mode. 

n

 System reaction: 

the system will continue running even if accumulator pressure is insuficient, however, it is highly recommended to repair  it 

immediatly .

n

 Solution: 

the system has detected that the accumulator is damaged.   The load of air, the condition of the membrane and the state of the 

spherical housing should be checked and replaced if necessary.  

BLANK SCREEN.

n

 Warning:  

blank screen.

n

 Solution:

 check electric supply as well as the position of the voltage selector. In case that no faulty   conditions can be detected, 

contactthe technical service.

Simultaneous alerts are displayed on the LCD screen successively every 3 seconds. All  alerts can be acknowledged by  pressing  the

 On/off 

 

push-button in manual mode. 

WARNING: ONEMATIC

 has a volt-free contact with 1 A  maximum intensity for the transmission of signals to different types of alarm  equipment 

(optical, acoustics, etc). See connection diagram.

Summary of Contents for Onematic

Page 1: ...ual Simboli d avvertenza di questo manuale Avertissements inclus dans cette notice de service Risk by electric shock Riesgo de choque el ctrico Pericolo di scarica elettrica Danger par choc lectrique...

Page 2: ...DE W L3 V L2 U L1 400 V 230 V Three phase motor Moteur triphas Motor trif sico Motor a tre fasi 3 phase power supply Raccordement r seau triphas Alimentaci n general trif sica Alimentazione elettrica...

Page 3: ...nitoring the minimum water level in inlet tank This function is independent of the protective system against dry running and optional n Internal pressure transducer n Internal flow sensor n Control pa...

Page 4: ...cations located on the connection strip base n Pumps with three phase motors n Power supply of control unit connect L1 L2 L3 via a three pole motor protection switch recommended in OFF mode and ensure...

Page 5: ...reached the start pressure Choose the desired timing using the p q keys This is the delay to stop the pump once it has reached the stop pressure Choose the desired timing using the p q keys System is...

Page 6: ...ped after the 4th attempt it will be switched off until the damage is repaired n Solution check the state of the pump for example the impeller could be blocked Verify the current value entered in the...

Page 7: ...er It cannot be used for transport of other kinds of liquid It is recommended to use an accumulator in order to avoid continuous start stops due to the deterioration of taps valves and also to prevent...

Page 8: ...ar las alarmas originadas por irregularidades o problemas del sistema que se indican en pantalla Su uso es opcional n Conexiones para detecci n de nivel m nimo de agua en dep sito de aspiraci n Este s...

Page 9: ...i n adecuada a la potencia instalada siguiendo las indicaciones de laTabla 1 n Verificar la alimentaci n el ctrica Desmontar la tapa del circuito electronico y llevar a cabo las conexionesde acuerdo c...

Page 10: ...archa Mediante las teclas p q se escogera el tiempo deseado Configuramos el retraso en desconectar la bomba una vez se ha llegado a la presi n de paro Mediante las teclas p q se escogera el tiempo des...

Page 11: ...a por ejemplo que no haya ning n bloqueo del rotor etc Verificar que los datos introducidos en el menu de configuraci n respecto el consumo de la bomba sea el adecuado se recomienda entrar siempre una...

Page 12: ...el transporte de otros l quidos Se recomienda utilizar un tanque de expansi n para evitar el deterioro v lvulas as como para evitar golpes de ariete en instalaciones con v lvulas de gran di metro ATEN...

Page 13: ...n Connessioni per rivelamento del livello minimo d acqua nel serbatoio di aspirazione Questo sistema indipendente del sistema di sicurezza contro funzionamento a secco Il suo uso opzionale n Trasdutt...

Page 14: ...sicurarsi che essiste una presa di terra efficace L1 L2 L3 e mediante interruttore magnetotermico adeguato alla potenza installata e in posizione di spento OFF n Motore Collegare il motore a U V W e n...

Page 15: ...i sceglie il tempo desiderato Configuriamo il ritardo nello spegnere la pompa una volta raggiunta la pressione di fermata Mediante i pulsanti p q si sceglie il tempo desiderato Il sistema pronto per l...

Page 16: ...pa per essempio che non abbia nessun blocco nel rotore ecc Verificare che i datti introdotti nel men di configurarzione rispetto del consumo della pompa sia adeguato si raccomanda mettere sempre un in...

Page 17: ...vaso di espansione adeguato per ogni installazione con la finalit di evitare avviamenti innecesari dovuti a gociolamenti per deteriori inevitabili di rubinetti valvole ecc cos come per evitare possib...

Page 18: ...surveillance du niveau d eau minimum dans la b che d alimentation Cette fonction optionnelle est ind pendante de la protection manque d eau n Capteur de pression int gr n Capteur de d bit int gr n Cla...

Page 19: ...ions sur le bornier n Pompes quip es de moteur triphas n Alimentation de l appareil de commande r aliser le raccordement hors tension des conducteurs L1 L2 et L3 en pr voyant un disjoncteur moteur 3 p...

Page 20: ...ouches p q 0 1 2 3 4 7 8 9 10 INT MAXI SENSEUR NIVEAU NON MODE OPERATION MARCHE ARRET MODE OPERATION MANODEBITMETRIQUE P MARCHE 05 0 bar PLINE PMARCHE 05 0 03 0 PLINE INT F 05 0 9 0 1 TEMP DEMARRAGE 0...

Page 21: ...t n Solution contr ler l tat de la pompe La roue pourrait tre bloqu e par exemple V rifier la valeur d intensit r gl e dans le menu de configuration il est conseill de r gler l intensit une valeur de...

Page 22: ...s filtres pour viter l obstruction du capteur de d bit Onematic est destin tre utilis pour l eau claire L appareil ne doit pas tre utilis pour d autres liquides La mise en uvre d un r servoir sous pre...

Page 23: ......

Page 24: ...130502D_v10...