8
8. CONTROL PANEL .
1 -
DIGIT DISPLAY
. In
AUTOMATIC
mode it shows instantaneous pressure (bar), instantaneous current com
-
sumptions (A) and minimum speed (Hz).
2 -
MANUAL START-STOP
pushbutton. It allows to start and stop manually the pump.
3 - Pushbutton
MENU
for enter or quit the menu.
4 - With the
↑↓
pushbuttons we can increase or dicrease programming values showed in the screen.
5 -
SET
for saving programmed values. Every pulsation is succeeded by a new field of the
CONFIGURATION
MENU
. Whenever we want to quit the configuration sequence press
MENU
.
6 - Led lights:
•
LINE
green: Electric supply. Bright when it is connected.
•
FAILURE
red: Bright or flashing depending on type of failure.
•
PUMP
yellow: When it is bright means pump working. It is lit with the pump stopped or when the device
is not connected.
•
AUTOMATIC
green: it is bright in
AUTOMATIC
mode.
7 - Pushbutton
ON/OFF
: It allows to change from
AUTOMATIC
to
MANUAL
mode or vice versa.
9. START UP (plug&play).
Be sure that the pump is correctly primed.
Connect the device to the electric supply with the magnetothermic switch, all the led lights will flash
instantaneously for a second. Screen will show
SP
(Set Pressure) and then its default value 2,0 bar, both
displays are alternated in time periods of 1"/5". The device is plug&play following the next steps:
1. Set the nominal current of the pump following the instructions on chapter 10
2. Set the desired set pressure by mean of
↑↓
3. Press the push-button
AUTO
The device will start to operate and led light
AUTO ON/OFF
will light. The screen will show the instanta
-
neous pressure. Being in automatic mode and using the push-button
SET
we can change the display:
P
: instantaneous pressure (bar).
Fr
: instantaneous speed (Hz)
A
: instantaneous current consumption (A)
ºC