12. ALARMS

In case of simultaneous alarms, quit the automatic mode and go to manual mode, pressing  the pushbutton 

AUTOMATIC ON/OFF

 (led light PUMP will turn off). Using keys 

↑↓

 will be displayed the succesive alarms. 

Once visualized, for leaving the menu,  press 

ENTER

 returning to 

MANUAL

 mode. 

A1 DRY RUNNING (

 Failure verification -    Final failure)

DESCRIPTION: if the system detects dry running during more than 10 seconds, it will stop the pump and the 

ART (Automatic ResetTest) will be activated. 

SYSTEM REACTION: after 5 minutes ART system will start again the pump during 30 seconds, trying to resto

-

re the system. In case of persistent lack of water, it will try it again every 30 minutes for 24 hours. If after all 

these cycles , the system still detects lack of water, the pump will remain permanently out of order until the 

damage will be repaired.

SOLUTION: 

Dry running: you should verify the feeding of the hydraulic network. The pumps can be primed using the 

push-button 

START/STOP

 ( the led light 

AUTOMATIC

 should be off, if it is not, press the push-button to 

disable it).

Special case: if the pump cannot provide the programmed pressure (configuration mistake) the device re

-

acts as it was dry-running.

Special Case 2: this device manages the dry running control through the nominal current consumption of 

the pump. It must be verified  the introduced current consumption in the setup menu (see paragraph 10).

A2 OVERCURRENT( 

 Failure verification -    Final failure)

DESCRIPTION: the  pump is protected against over currents by mean of the intensity value established in 

the installation menu. These over currents are produced generally by dysfunctions in the pump or in the 

electric supply.

SYSTEM REACTION: when detecting the thermal failure, the pump will be automatically stopped. The  sys

-

tem will try again to restart the  pump when the demand of consumption require it. The control system will 

carry out 4 attempts in this circumstances. If the system remain locked after the 4th attempt, the  pump will 

remain definitively out of order.

SOLUTION: verify the state of the pump, for example the impeller could be blocked. Verify intensity values 

introduced in the configuration menu. Once the problem have been solved the operation will be restored  

going to the configuration menu (see chapter 10) and configuring the adequated current value.

A3 DISCONNECTED P. ( 

 Final failure)

DESCRIPTION: the device has an electronic safety system in case of no load detection.

SYSTEM REACTION: the device is disconnected.

SOLUTION: the wound of the motor and the pump consumption should be verified. Once the problem has 

been solved the operation will be restored  going to the configuration menu (see chapter 10) and  introdu

-

cing the  adequate intensity value. 

A5 TRANSDUCER ( 

 Final failure)

DESCRIPTION: the transducer damages are showed in the  device LCD screen.

SYSTEM REACTION: the device operation is interrupted.

SOLUTION: contact with technical service.

A6 EXCESSIVE TEMP. ( 

 Final failure)

DESCRIPTION: the system has a cooling device to keep the INVERTER  in optimum working conditions.  

SYSTEM REACTION: if an excessive temperature is reached the own system leaves the inverter out of servi

-

ce and as consequence the pump too.

SOLUTION: verify  the temperature of the water, it should be under 40 ºC and the temperature environ

-

ment should be under 50 ºC.  Contact with technical service.

A7 SHORTCIRCUIT ( 

 Final failure)

DESCRIPTION: the device has an electronic system for protection against short circuits as well as peaks of 

current.

SYSTEM REACTION: the pump remains stopped for 10". Then it starts again - 4 attempts. If the problem is 

not solved, the  pump will remain definitively out of order. 

SOLUTION: check the pump, if the problem persists, contact the technical service.

A8 OVERVOLTAGE -  A9 UNDERVOLTAGE ( 

 Failure verification)

DESCRIPTION: the device has an electronic safety system against overvoltages and too low supply voltages.

SYSTEM REACTION: in case of overvoltage or undervoltage the system remains stopped until an adequate 

value of voltage is reached. In this case,  the system is automatically restored.

SOLUTION: check the electric supply.

------

DESCRIPTION: blank screen.  

SOLUTION: check the electric supply 127-230 V.

Summary of Contents for Ecodrive

Page 1: ...N AND OPERATING INSTRUCTIONS IT ISTRUZIONI D INSTALLAZIONE E USO FR INSTRUCTIONS POUR L INSTALLATION ET L EMPLOI ES INSTRUCCIONES PARA LA INSTALACI N Y UTILIZACI N DE INSTALLATIONS UND BEDIENUNGSANLEI...

Page 2: ...e L apparecchio deve funzionare con un flusso d acqua limpido nel caso che essista la possibilit di presenza di ghiaia o particelle installazioni con pompe sommerse raccomandato usare un filtro adegua...

Page 3: ...ov lvulas o v lvulas con un paso de caudal considerable ATENCION antes de realizar cualquier manipulaci n en el interior del aparato deber ser desconectado de la red el ctrica y se esperar un m nimo d...

Page 4: ...4 BODY CONNECTIONS COLLEGAMENTO CORPO CONNEXIONS DU CORPS CONEXIONES CUERPO ELE KTRISCHE ANSCHL SSE LATERAL CONNECTION COLLEGAMENTO LATERALE CONNEXION LAT RALE CONEXION LATERAL SEIT LICHER FIG 2 FIG 1...

Page 5: ...ables pero no imprescindibles B En el caso del tanque hidroneum tico 7 se recomienda su utilizaci n en instalaciones donde se pretenda evitar el golpe de ariete HINWEISE A Die Zubeh rteile 3 4 5 und 8...

Page 6: ...m 1 5 bar Pw 1 5 bar Pc 15 x 0 033 bar 0 5 bar Prmin 1 5 1 5 0 5 3 5 bar 2 CLASSIFICATION AND TYPE According to EN 60730 1 this product is a device of independent assembly type 1B with software of cla...

Page 7: ...Before proceeding with hydraulic connection it is essential to install a non return valve in the pump s inlet or outlet The device must be connected in vertical position FIG 3 the inlet port G1 male d...

Page 8: ...OMATIC green it is bright in AUTOMATIC mode 7 Pushbutton ON OFF It allows to change from AUTOMATIC to MANUAL mode or vice versa 9 START UP plug play Be sure that the pump is correctly primed Connect t...

Page 9: ...ome back to the main display This is all the sequence REGISTER HOURS HF Counter of total time that the device has been operating REGISTER PUMP HOURS HP Counter of total time that the pump has been ope...

Page 10: ...will remain definitively out of order SOLUTION verify the state of the pump for example the impeller could be blocked Verify intensity values introduced in the configuration menu Once the problem have...

Page 11: ...con pompe situate nel livello 0 Hm 15 m 1 5 bar Pw 1 5 bar Pc 15 x 0 033 bar 0 5 bar Prmin 1 5 1 5 0 5 3 5 bar 2 CLASSIFICAZIONE E TIPO Secondo EN 60730 1 l impianto un dispositivo di montaggio indip...

Page 12: ...massima d ordine 0 5 8 bar Protezione IP55 Temperatura max de l acqua 40 C Temperatura ambiente max 0 50 C Portata max 8 000 l h 6 INSTALLAZIONE IDRAULICA FIG 3 indispensabile installare una valvola...

Page 13: ...AUTOMATIC verde Si accende in modo automatico 7 ON OFF Permite passare dal modo AUTOMATICO a MANUALE e viceversa 9 MESSA IN MARCIA PLUG AND PLAY Procedere all adescamento della pompa Collegare il disp...

Page 14: ...principale premendo SET ancora La sequenza di visualizzazione come segue CONTATORE ORE HF Numero di ore di funzionamento dell apparecchio CONTATORE ORE POMPA HP Numero di ore di funzionamento della po...

Page 15: ...o stato della pompa per esempio che non abbia blocco nel rotore ecc Verificare che i dati introdotti nel menu di configurazione rispetto queli del consumo della pompa sia l adeguato Una volta risolto...

Page 16: ...quivalent 15 m avec la pompe situ e au niveau 0 Hm 15 m 1 5 bar Pw 1 5 bar Pc 15 x 0 033 bar 0 5 bar Prmin 1 5 1 5 0 5 3 5 bar 2 CLASSIFICATION ET TYPE Selon EN 60730 1 l quipe est un dispositif d as...

Page 17: ...Temp rature max de l eau 40 C Temp rature ambiance max 0 50 C D bit max 8 000 l h 6 INSTALATION HYDRAULIQUE FIG 3 Il est indispensable d installer un clapet anti retour l aspiration ou au refoulement...

Page 18: ...de AUTOMATIC 7 ON OFF pour passer du mode AUTOMATIC MANUEL et vice versa 9 MISE EN ROUTE PLUG AND PLAY Proc dez a l armor age de la pompe Branchez le dispositif au r seau lectrique au moyen d un disjo...

Page 19: ...an principale Celle ci est toute la s quence COMPTEUR HEURES HF Nombre d heures de fonctionnement de l appareil COMPTEUR D HEURES DE POMPE HP Nombre d heures de fonctionnement de la pompe COMPTEUR CIC...

Page 20: ...soit pas bloqu etc V rifier que les donn es introduites dans le menu de configuration soient correctes par rapport la consommation en amp res de la pompe A3 POMPE DEBRANCHEE Alarme d finitive DESCRIPT...

Page 21: ...la presi n de interven ci n de las bombas Ejemplo orientativo para un edificio de 5 pisos equivalente a 15 m con bomba situada en nivel 0 Hm 15 m 1 5 bar Pw 1 5 bar Pc 15 x 0 033 bar 0 5 bar Prmin 1 5...

Page 22: ...n m x de utilizaci n 15 bar Presi n m x de consigna 0 5 8 bar Protecci n IP55 Temperatura m x del agua 40 C Temperatura ambiente m x 0 50 C Caudal m x 8 000 l h 6 INSTALACI N HIDR ULICA FIG 3 Es indis...

Page 23: ...CO verde se enciende en modo autom tico 7 Pulsador ON OFF permite pasar modo AUTOMATICO a modo MANUAL y viceversa 9 PUESTA EN MARCHA PLUG AND PLAY Proceder al cebado de la bomba Conectar el dispositiv...

Page 24: ...o la secuencia pulsando MENU La secuencia de visualizaci n es la siguiente CONTADOR HORAS HF N mero de horas de funcionamiento del aparato CONTADOR HORAS BOMBA HP N mero de horas de funcionamiento de...

Page 25: ...ervicio SOLUCI N verificar el estado de la bomba por ejemplo que no haya ning n bloqueo del rotor etc Verifi car que los datos introducidos en el menu de configuraci n respecto el consumo de la bomba...

Page 26: ...d entspricht dem Druck der infolge der Pumpent tigkeit erreicht wird Ein zur Orientierung dienendes Beispiel f r ein f nfst ckiges Geb ude mit einer H he von 15 m ausgestattet mit einer Pumpe die sich...

Page 27: ...Ger t Ecodrive sollte in senkrechter Position montiert werden Abb 3 Die Eingangs ffnung Einschraub gewinde G 1 muss direkt an den Antrieb der Pumpe und der Ausgang Einschraubgewinde G 1 ans Netz ange...

Page 28: ...Ist es ausgeschaltet so steht die Pumpe still oder es ist keine Spannung in der Leitung vorhanden AUTOMATIC gr n Dieses Licht leuchtet in der automatischen Betriebsart 7 Schalttaste ON OFF Sie erm gli...

Page 29: ...MENU w hrend 3 gelangt man in das Register der Betriebsdaten und Alar me mit ENTER kann das Register durchbl ttern nach Beendigung der Sequenz kommt man zur ck zur Hauptanzeige Dies ist die gesamte S...

Page 30: ...n eingegebenen Daten bez glich des Stromverbrauchs der Pumpe zul ssig sind Nach Behebung der St rungsursache muss f r die neuerliche Inbetriebnahme der Pumpe ber das entsprechende Men feld Zugriff auf...

Page 31: ...2015 863 Norme europee armonizzate UNE EN 60730 1 1998 A11 1998 A2 1998 A14 1998 A15 1998 A20 1998 A17 2001 ERRATUM A1 2001 A18 2003 UNE EN 60730 2 6 1997 A1 1998 A2 1999 CORR A1 2001 CORR A2 01 UNE...

Reviews: