Settings
98-175666-A
Chapter 4: Setup of the antenna
4-19
• Dashboard and profile
• Tracking receiver
To download the BDU MIB file directly, do as follows:
1. Click the link
SNMP MIB file download
and
save the file on your computer.
Telnet access
You can enable
Telnet access
to access the antenna via a command line interface.
SSH command line interface is enabled by default.
Diagnostics report
This report contains information from the ADU and BDU that are relevant for the service
personnel during troubleshooting. The report contains data for the selected download
intervals. You can send automatically generated diagnostic reports at fixed intervals. It is
also useful documentation of the current setup and contains all parameters set during
configuration. The main sections of the diagnostics report are:
• Software
• System
• Hardware
• Setup - System data
• Calibration - Calibration Data
• Blocking zones - Blocking zone configuration
• Network - LAN Configuration
• Modems - Modem profiles
• Satellites - Satellite profiles
• Operation - Current modem and navigation parameters.
• POST - results of the Power-On-Self-Test
• Active Events - lists the currently active events
• Events - List of all cleared events.
• System log
To set up sending a diagnostics report, do as follows:
1. Click
Settings > IoT & Management
.
2. In the section
Diagnostics report
enter the following:
• E-mail sender.
• E-mail recipients (comma separated).
• Send interval: Select
Daily, Weekly
or
Monthly
.
3. Click
Apply.
Note
None of the SNMP values need to be polled more often than once a minute.
Polling SNMP values more frequently will impact the performance of the SAILOR
XTR Ka.