Settings
98-175666-A
Chapter 4: Setup of the antenna
4-18
• STARTTLS to upgrade SMTP to Secure Socket Layer (SSL) or Transport Layer Security
(TLS): IP port 587.
Contact your IT department for the specific data. To set up e-mail, do the following:
1. Go to
Settings > E-mail setup.
2. Enter the data for Outgoing mail server (SMTP) and SMTP port number.
SMTP: SMTP over port 25
SMTPS: SMTP SSL/TLS encrypted over port 465.
STARTTLS: SMTP with STARTTLS upgrading to encrypted over port 587.
3. Select SMTP type.
4. Select SMTP authentication. If you have selected
Credentials
, you must specify a User
name and password. This data is typically provided by your IT department.
Remote syslog
The antenna can send each syslog message to a syslog server to advise the system
administrator of the current status of the antenna. To set up sending syslog messages to a
syslog server, do as follows:
1. Select
Settings > IoT & Management
.
2. In the section
Remote syslog
select
Remote syslog enabled
(default: not ticked).
3. Enter the address of the remote syslog server.
4. Click
Apply
.
SNMP
SNMP traps, or notifications, are network packets which advise the system administrator
about significant events in the antenna, e.g. alarms and system error messages. They are
generated by the antenna and can be sent automatically to an SNMP trap
receiver/manager. The event time is UTC time. In this section there is a link from which you
can download the SNMP MIB file. To set up reporting SNMP traps to an SNMP server, do as
follows:
1. Select
Settings > IoT & Management
.
2. In the section
SNMP
select
SNMP enabled
(default: not ticked).
3. Enter the SNMP traps address.
4. Enter the SNMP traps Community name. This is the name of the SNMP trap
receiver/manager. This is needed for authentication of the SNMP trap request.
5. Click
Apply
.
The SAILOR XTR Ka supports SNMP v2 requests to retrieve configuration and present
settings. SNMP is always enabled on all Ethernet interfaces. The SNMP community string is
public
. The SAILOR XTR Ka offers via SNMP most of the data that are available from the
DASHBOARD web pages. Detailed documentation about supported OIDs can be found in
the MIB file. The MIB entries are grouped as shown below:
• System configuration
• Navigation coordinates
• Antenna pointing
Note
You must set
Outgoing mail server
to an IP address if DNS has not been set up
in
DNS setup
in