D/I Mux III User’s Manual
Appendix I. Traps and Modem Dial Out Configuration
289
SELECT TRAP CRITERIA
By selecting option 8 the
AMCU
is now told that if a
CGA
(
C
arrier
G
roup
A
larm) occurs to send a
linkDown
Trap to the SNMP Manager.
15:43:53 --------[ Set T1 Line Trap Criteria - T1 One ]-------- 06/19/97
If any alarm marked Check is present, the T1 line will be considered
down. Unmarked alarms are ignored.
------------------------------------------------------------------------
0: Receive Far End LOF (Yellow) ..... [ ]
1: Transmit Far End LOF (Yellow) .... [ ]
2: Receive AIS (Blue) ............... [ ]
3: Transmit AIS (Blue) .............. [ ]
4: Near End Loss Of Frame (Red) ..... [ ]
5: Near End Loss Of Signal .......... [ ]
6: Loopback ......................... [ ]
7: Bypass ........................... [ ]
8: Carrier Group Alarm .............. [Check]
9: Delayed Carrier Group Alarm ...... [ ]
A: Any Alarm
N: None
Q: Quit
------------------------------------------------------------------------
Chose a number to change the state of that alarm, or chose a letter for
the specified action: [Q]
Figure J-3 Trap Criteria Selected
Summary of Contents for D/I Mux III System
Page 20: ......
Page 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Page 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Page 79: ...Chapter 3 Installation 59 ...
Page 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Page 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Page 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Page 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Page 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...