![Coastcom D/I Mux III System User Manual Download Page 142](http://html.mh-extra.com/html/coastcom/d-i-mux-iii-system/d-i-mux-iii-system_user-manual_2628616142.webp)
Chapter 4. Configuration and Operation
122
DV - Displaying Smart AC Power Supply Parameters
Enter
DV
to Display the parameters of the 110 Volt Smart AC power supply (P/N 30308-102). Note that
the option to select
DV
is only available when a Smart AC power supply is installed in the D/I Mux III
system. Figure 4-21 depicts the
DV
screen.
] DV
10:03:19----------------- [ PS 1 : AC/DC ]----------------- 03/08/95
Minus 12V : -12.1 Plus 12V : 12.0
Minus 5V : - 5.0 Plus 5V : 5.0
Minus 48V : -48.4
SB Fuse : OK
Ringing Generator
-----------------
Voltage : 266.8 V[p-p]
Trip Margin : 83.0 V
Frequency : 20 Hz
Minor Alarm : Enabled
---Hardware--- Serial Software
Card Type Part Number Rev Number Revision
----------------------------------------------------------------------
AC/DC 30308-101 B 113611-0017 B 9/26/91
----------------------------------------------------------------------
Figure 4-21. Displaying the Smart AC Power Supply Parameters
Summary of Contents for D/I Mux III System
Page 20: ......
Page 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Page 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Page 79: ...Chapter 3 Installation 59 ...
Page 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Page 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Page 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Page 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Page 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...