Chapter 5. Diagnostics
203
Error
Message
Cause
Solution
Invalid Slot Range
(1-N)
Slot range entered was not a number
between 1 and 8 for the 8-slot shelf; or not
a number between 1 and 12 for the 12-slot
shelf; or not a number between 1 and 24
for the 24-slot shelf; or the first number of
the range was greater than the second
number.
Check the range, then enter the
numbers again. (To check for proper
shelf size, use the
SP
command.)
LIU B Slot is
Empty
Self explanatory.
Informational message only; no action
required.
LIU A Slot is
Empty
Self explanatory.
Informational message only; no action
required.
Lower Strobe Card
Not Installed
Self explanatory.
Informational message only; no action
required.
Lower Strobe
Error
Self explanatory.
Check the lower strobe card and retry
operation.
Map is Working
This map is the working map and its
status cannot be modified or changed
while it is the working map.
Make another map the working map
(copy the working map), or choose
another map to modify.
Map Not Enabled
A disabled map cannot be made the
working map.
Change the status of the map to
Enabled
before making it the working
map.
Original Alarm
Map Working
Only one alarm map can be enabled at a
time. Another alarm map is already
enabled and its status cannot be changed
because it is currently the working map.
Normally, when a second alarm map is
enabled, the first alarm map is disabled,
unless it is the working map.
Change the first alarm map so that it is
not the working map. Then try again to
change the status of the second alarm
map to
Enabled
.
Original Event
Map Working
Only one event map can be enabled at a
time. Another event map is already
enabled and its status cannot be changed
because it is currently the working map.
Normally, when a second event map is
enabled, the first event map is disabled,
unless it is the working map.
Change the first event map so that it is
not the working map. Then try again to
change the status of the second event
map to
Enabled
.
Original Time Map
Working
Only one time map can be enabled at a
time. Another time map is already
enabled and its status cannot be changed
because it is currently the working map.
Normally, when a second time map is
enabled, the first time map is disabled,
unless it is the working map.
Change the first time map so that it is
not the working map. Then try again to
change the status of the second time
map to
Enabled
.
Password Already
Used
Duplicate passwords are not allowed.
Select and enter another password.
Password Table
Full
A maximum of eight passwords are
allowed, and eight are already entered.
Delete an already-defined password,
then enter the new password.
Request is Not
Allowed
Self explanatory.
Make corrections and retry. If
appropriate, respond to system prompts
to correct the problem.
Summary of Contents for D/I Mux III System
Page 20: ......
Page 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Page 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Page 79: ...Chapter 3 Installation 59 ...
Page 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Page 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Page 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Page 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Page 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...