Chapter 3. Installation
96
110 V AC Power Supply Installation
Following is the procedure for installing the 110 V AC power supply. Follow the steps in
the order given. Refer to Figure 3-25 for jumper locations on the power unit.
1.
Remove any nut which may be attached to the back of the power supply, or on the
grounding lug which may have been installed there for shipping purposes.
2.
Slide the power supply into the AC/DC PWR slot until the card's edge firmly
engages the connector fingers. The slot will have a rectangular opening for the cord
to fasten through the backplane, and a hole for the grounding lug. Install the card
as follows:
•
8-Slot:
Card slot marked AC/DC PWR, the first from the right card slot
•
12-Slot:
Card slot marked AC/DC PWR, the top right slot, the bottom of the card
toward the left of the shelf
•
24-Slot:
Card slot marked AC/DC PWR, third card slot from the left on the upper
shelf
3.
Install the #10-32 ground nut previously removed in Step 2, or packed loosely on
the lug at the rear of the system. Tighten the nut to secure grounding, but do not
tighten excessively. Excessive tightening can damage the backplane, connector,
and bracket on the supply.
4.
Complete the common equipment installation and cabling before powering up the
system.
5.
The AC power is connected through the rear of the unit with a standard IEC line
cord (supplied with the unit). Connect the line cord through the opening in the
backplane to the supply.
6.
Connect the plug end of the line cord to a 110 V AC, 50-60 Hz properly grounded
source.
7.
Ensure that the terminal block's protective covers are in place after installation.
Voltages are marked on the terminal block’s terminals.
8.
Observe that the green indicator is lit. If the red indicator is lit, the supply or the
system has a fault which must be cleared.
Removal of the 110 V AC Power Supply
The following is the procedure for removing the 110 V AC Power Unit.
1. Remove the line cord plug from the 110 V AC source and unplug the cord from the
back of the system.
2. Remove the grounding lug nut at the rear of the system near the rectangular opening
for the line cord.
3. Gently tap or push the grounding stud at the rear of the system with a nut driver
handle, malleable handle, or a piece of wood to remove the supply.
4. After removing the power supply from the slot, refasten the nut removed in Step 2
back onto the lug. Gently tighten the nut.
5. Place the power supply in a static-shielded bag.
Summary of Contents for D/I Mux III System
Page 20: ......
Page 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Page 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Page 79: ...Chapter 3 Installation 59 ...
Page 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Page 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Page 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Page 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Page 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...